NonStop NS2400 Series Planning Guide

12 Hardware Configuration in NS2400T and NS2400ST
Cabinets
This chapter shows the example locations of hardware components within the NS2400T and
NS2400ST systems. It also describes the maximum number of components allowed in these systems
and the coexistence limits for CLIMs.
Maximum Number of Modular Components, NS2400T and NS2400ST
Systems
This table shows the maximum number of the modular components installed in an NS2400T or
NS2400ST system. These values might not reflect the system you are planning and are provided
only as an example, not as exact values.
NonStop NS2400T or NS2400ST systemEnclosure or Component
1
4-processor2-processor
42Blade element (rx2800 i4)
22VIO enclosure (DC-powered)
44Storage CLIM CG
22IP CLIM CG
22Telco CLIM CG
11CLIM patch panel CG
21Fuse panel
84SAS CG disk enclosure
22Maintenance Switch
1
For information about coexistence limits for IP and Telco CLIM CGs, see “IP and Telco CLIM T CG Coexistence Limits ”
(page 149).
IP and Telco CLIM T CG Coexistence Limits
Your NonStop NS2400T or NS2400ST system supports the following combinations of IP and Telco
CLIM CGs:
CLIM T CG Coexistence Limits
6 Supported Combinations
Telco CLIM CGIP CLIM CG
00
01
10
11
02
20
Maximum Number of Modular Components, NS2400T and NS2400ST Systems 149