NonStop NS2400 Series Planning Guide

Ethernet Cables
Ethernet connections for a dedicated service LAN require CAT 5e or CAT 6 unshielded twisted-pair
(UTP) cables.
SWAN Concentrator Restrictions
NOTE: SWAN and SWAN 2 concentrators are only supported on the NonStop NS2400
commercial system. SWAN/SWAN 2 concentrators can be connected to an IP CLIM or the 10/100
Ethernet ports on a VIO enclosure with these restrictions:
Isolate any ServerNet wide area networks (SWANs) on the system. The system must be
equipped with at least two LANs: one LAN for SWAN/SWAN 2 concentrators and one for
the dedicated service LAN.
Most SWANs are configured redundantly using two or more subnets. Those subnets also must
be isolated from the dedicated service LAN.
Do not connect SWANs on a subnet containing a DHCP.
Dedicated Service LAN Links
You can implement up-system service LAN connectivity using:
“Dedicated Service LAN Links With Two VIO Enclosures” (page 158)
“Dedicated Service LAN Links With IP CLIMs” (page 158)
“Dedicated Service LAN Links With Telco CLIMs” (page 159)
Dedicated Service LAN Links With Two VIO Enclosures
You can implement up-system service LAN connectivity using the Ethernet ports on two VIO
enclosures. The values in this table show the identification for the Ethernet ports in slot 6B, port A
of both VIO enclosure modules (module 2 and module 3) and connected to the maintenance switch:
IP ConfigurationTCP/IP StackEthernet LIFEthernet PIFGMS for Ethernet Port
Location in VIO
Enclosure
IP: 192.168.36.10$ZTCP0L1002RG10026.0.A100.2.6b Port A
Subnet: %FFFF0000
Hostname: osmlanx
IP: 192.168.36.11G$ZTCP1L1003RG10036.0.A100.3.6b Port A
Subnet: %FFFF0000
Hostname: osmlany
Dedicated Service LAN Links With IP CLIMs
You can implement up-system service LAN connectivity using IP CLIMs, if the system has at least
two IP CLIMs. The values in this table show the identification for the IP CLIMs in a NonStop NS2400
series system and connected to the maintenance switch. For example, in this table an IP CLIM
named N100241 is connected to slot 4, port 1 of the VIO enclosure located in group 100, module
2.
IP ConfigurationTCP/IP StackGMS for IP CLIM Location in VIO
Enclosure
IP: 192.168.36.10$ZTCP0100.2.4.1
Subnet:
%hFFFFFF00
158 Maintenance and Support Connectivity