RDF System Management Manual for H-Series RVUs (RDF 1.8)
Recovery This is an informational message; no recovery is required.
27
Lockstep Gateway Started.
Cause The lockstep gateway is started.
Effect The lockstep gateway continues its initialization activity.
Recovery This is an informational message; no recovery is required.
28
RDF extractor procname responded with error errnum to lockstep request.
procname
is the name of an extractor process.
errnum
is a file-system error number.
Cause While the extractor is processing a lockstep request, the gateway stops, has been
restarted by SCF, and has sent a new lockstep request to the extractor.
Effect The lockstep gateway stops.
Recovery SCF automatically restarts the gateway. If the problem persists and the autorestart
count is exhausted, wait 30 seconds and then restart the gateway again.
29
Lockstep transaction aborted with error errnum.
errnum
is a file-system error number.
Cause The specified error was encountered on a lockstep transaction.
Effect If the error is retryable, the lockstep gateway starts a new transaction. If the error is
unexpected, the gateway stops.
Recovery This is an informational error, unless the gateway stops. If it stops, correct the
condition that caused the error and then restart the gateway.
30
ENDTRANSACTION error errnum encountered on lockstep transaction.
errnum
is a file-system error number.
Cause The specified error was encountered on ENDTRANSACTION.
Effect If the error is retryable, the lockstep gateway starts a new transaction. If the error is
unexpected, the gateway stops.
Recovery This is an informational error, unless the gateway stops. If it stops, correct the
condition that caused the error and then restart the gateway.
31
Invalid process name: procname for the RDF master extractor.
procname
is the invalid process name.
Cause In your SCF script for starting the lockstep gateway, the process name specified in
the STARTUPMSG attribute was not a valid process name for the RDF master extractor.
Effect The lockstep gateway stops.
Recovery Correct the STARTUPMSG attribute script and then manually delete the RDF
lockstep gateway process from SCF and run your newly edited SCF script. The process name
must not include a node name.
Lockstep Gateway Event Messages 341