RDF System Management Manual for H-Series RVUs (RDF 1.8)

745
Audit record conversion error error
error
is the error number.
Cause The extractor encountered the specified error while attempting to convert an audit
record from one version to another.
Effect The extractor abends, thereby stopping the other RDF processes.
Recovery This is an internal error. Contact your service provider.
746
Error during program initialization
Cause A fatal error occurred during RDF subsystem initialization.
Effect RDF stops. Error 743 should follow this message.
Recovery Check the EMS event log for any preceding errors that might indicate the source
of the problem. If it is possible to correct the underlying problem, then RDF can be restarted.
747
Volume must be a TMF datavol volume
volume
is the name of the volume on the remote node that must be added to the TMF configuration
as a data volume.
Cause Either TMF has not been started on the remote node, or the volume associated with
this updater on the remote node has not been added as a datavol in the TMF configuration.
TMF must be started on the remote node, and the volume associated with this updater on the
remote node must be added as a datavol to this remote TMF configuration.
Effect The updater will not start.
Recovery Start TMF on the remote system and add the associated volume as a datavol in
the TMF configuration. Additionally, you should start the volume for transaction processing.
748
Internal error - RDF extractor abending
Cause The extractor has detected an audit record of an unknown version.
Effect The extractor process abends.
Recovery This is an internal error. Contact your service provider.
749
Old audit record format encountered
Cause The extractor has detected an audit record generated by an unsupported version of
TMF.
Effect The extractor abends.
Recovery Reinitialize RDF. You might need to resynchronize the primary and backup
databases.
750
Failure to obtain TLE for SIGNALTIMEOUT
Cause All RDF processes rely upon the ability to post timers by calling SIGNALTIMEOUT
and take action when those timers expire. This message indicates that a call to
SIGNALTIMEOUT failed because there were insufficient time list elements (TLEs) available.
Effect The process continues to run, but recovery is required.
354 Messages