the extractor can log messages 766, 767, and 768 again, even if it had logged any of them
prior to the restart condition.
Determining When Online Database Synchronization Is Complete
The following RDF messages assist you in knowing when the various phases of online database
synchronization are complete:
Extractor Messages
Messages 766, 767, and 768 in combination report the completion of phase 1. Message 782
reports the completion of phase 2. Message 782 indicates that the extractor has finished its
involvement in the online synchronization operation.
Updater Messages
Message 782 reports the completion of phase 2 and indicates that the updater has finished its
involvement in the online synchronization operation. Even in a partial database synchronization,
all updaters will log event 782 because, in a partial database synchronization, you follow the
guidelines of a complete database synchronization, except that you are only loading the specific
volumes, table, and files you need. Therefore all updaters log the 782 event.
Additionally, the STATUS RDF display has been enhanced to identify which database volumes are
still being synchronized. That information is reported in the error column of the display. If a volume
is still being synchronized, its entry in the error column is sync. As soon as a volume is successfully
synchronized, its entry in the error column is blank. If an updater encounters an error during
synchronization, the associated entry in the error column is ****.
The following sample display shows that the updater process $MUP1 for the data volume $DATA1
has successfully completed synchronization while the updater process $MUP2 for the data volume
$DATA2 is still doing the synchronization:
RDF Process Name RTD Time Pri Volume Seqnce Rel Byte Addr Cpus Err
------------------ ------ --------- --- ------- ------ ------------- ----- ----
Monitor $MMON 185 $TRAILS 5 2: 3
Extractor (0) $MEXT 0:00 185 $TRAILS 5 7110636 1: 2
Receiver (0) $MRCV 0:00 185 $TRAILS 37 806912 1: 2
$DATA06 -> $DATA06 $MUP1 0:00 185 $TRAILS 37 806912 1: 2
$DATA07 -> $DATA07 $MUP2 1:59 185 $TRAILS 32 712704 2: 3 sync