RDF System Management Manual for J-series and H-series RVUs (RDF 1.10)

Cause
In your SCF script for starting the lockstep gateway, the process name specified in the
STARTUPMSG attribute was not a valid process name for the RDF master extractor.
Effect
The lockstep gateway stops.
Recovery
Correct the STARTUPMSG attribute script and then manually delete the RDF lockstep gateway
process from SCF and run your newly edited SCF script. The process name must not include a
node name.
32
A spurious STARTUPMSG argument was encountered for the lockstep gateway.
Cause
In your SCF script for starting the lockstep gateway, the STARTUPMSG attribute contained an
extra or unrecognizable argument.
Effect
The lockstep gateway stops.
Recovery
The STARTUPMSG attribute must include exactly two arguments: the word ENABLE or DISABLE,
and a valid RDF extractor process name, all enclosed in quotes. Correct the STARTUPMSG
attribute script and then manually delete the RDF lockstep gateway process from SCF and run
your newly edited SCF script. The process name must not include a node name.
306 Process-Lockstep Operation