error
is the file-system error number that identifies the specific error.
Cause
A call to the checkpoint procedure failed, and the backup process of a NonStop process pair
is still running. The message includes the number of the file-system error that was encountered
when the primary process was trying to communicate with the backup process.
Effect
The backup process is stopped, and a new one is created after about 15 seconds.
Recovery
See the description of the CHECKPOINT procedure in the Guardian Procedure Calls Reference
Manual to determine the cause of the failure. If possible, correct the underlying cause to avoid
its reoccurrence.
715
Primary stopped
Cause
The primary process of a NonStop process pair has stopped. This probably was the result of an
operator inadvertently issuing a STOP command from TACL.
Effect
The backup process takes over, but not in fault-tolerant mode, until the primary process can be
re-created.
Recovery
This is an informational message; no recovery is required.
716
Primary abended
Cause
The primary process of a NonStop process pair has abended.
Effect
The backup process takes over, but not in fault-tolerant mode, until the primary process can be
re-created.
Recovery
Scan the EMS event log to determine why the process abended. An INSPECT SAVEABEND file
should have been created in the volume and subvolume where you placed the RDF/IMP software;
you should save that file for problem resolution by your service provider.
717
Primary processor down
Cause
The primary CPU of a NonStop process pair has stopped.
Effect
The backup process takes over, but not in fault-tolerant mode. The primary process will be
re-created after its CPU is reloaded.
Recovery
Reload the downed processor.
718
Switched to original primary processor
352 Messages