RDF System Management Manual for J-series and H-series RVUs (RDF 1.10)

Effect
The validation fails.
Recovery
Alter the configuration to include the monitor.
No PCB available
Cause
A NEWPROCESS error occurred during START RDF or TAKEOVER processing.
Effect
The command fails.
Recovery
Check system resource utilization. When resources become available, reenter the command.
No RECEIVER is Configured
Cause
The RDF configuration file is invalid.
Effect
The configuration validation fails.
Recovery
Check the receiver parameter entries in the configuration file for invalid values and correct any
errors found.
No VOLUMEs are configured
Cause
The RDF configuration file is invalid.
Effect
The configuration validation fails.
Recovery
Check the updater process parameters in the configuration file for invalid values and correct
any errors found.
No VOLUMES are configured for ATINDEX atindex
Cause
You added an extractor and receiver with the specified ATINDEX, but there are no updaters
with that value.
Effect
The validation fails.
Recovery
Add at least one updater with the same ATINDEX value or delete the particular extractor-receiver
pair.
Obtained error error# in attempting to examine remote imagetrail files
error#
is the file-system error number that identifies the specific error.
Cause
The COPYAUDIT command encountered the specified error in attempting to read the remote
image trail files.
Effect
The command fails.
436 Messages