CONTROLBUF Operations
232 Emit the current month as MMM.
233 Emit the current month as MM.
234 Emit the current year as YY.
235 Emit the current year as YYYY.
236 Emit the NetBatch batch ID as ZZZ9.
237 Emit the second 8 bytes of the NetBatch batch name (if any) with trailing
sp
aces deleted.
238 Emit the first 8 bytes of the NetBatch batch name (if any) with trailing
sp
aces deleted.
239 Emit the second 8 bytes of the job FORM name with trailing spaces
de
leted.
240 Emit the first 8 bytes of the job FORM name with trailing spaces deleted.
241 Emit the FASTPXNS print process version as DDMMMYY.
242 Emit the device name on which this job is being printed.
243 Emit the FASTPXNS print process object file name as
$vo
l.subvol.file.
244 Emit the FASTPXNS print process name with trailing spaces deleted.
245 Emit the Spooler supervisor name with trailing spaces deleted.
246 Emit the EXPAND node name with trailing spaces deleted.
247 Emit the job OWNER name with trailing spaces deleted.
248 Emit the job OWNER group with trailing spaces deleted.
249 Emit the job number as ZZZ9.
250 Emit the job OWNER number as ZZ9,ZZ9.
251 Emit the second 8 bytes of the job location (LOC) with trailing spaces
de
leted.
252 Emit the first 8 bytes of the job location (LOC) with t
railing spaces deleted.
253 Emit the second 8 bytes of the job REPORT name with trailing spaces
de
leted.
254 Emit the first 8 bytes of the job REPOR
T name with trailing spaces
deleted.
255 Emit a single byte of value 255.
Token 255 is used if the text embedded in the CONTROLBUF buffer for
printing needs to contain bytes with all bits on (255). Two consecutive
bytes of 255 tell FASTPXNS that this is not a token but a single byte of
255 that should be emitted.
Table 7-5. Token Values for FASTPXNS CONTROLBUF 112 (page 2 of 2)
Token Value Action