Spooler FASTP Network Print Processes Manual

EMS Messages
Spooler FASTP Network Print Processes Manual 427528-007
B - 36
FASTPTCP Event Messages
61
proc-name
is the process name of the FASTPTCP process.
device-name
is the Spooler device name.
Cause. The FASTPTCP process could not find a device record for the specified
device in a FASTKCON or FASTCNFG file. This message is accompanied by message
number 60.
Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is
placed offline.
Recovery. Add the device record to FASTCNFG as described in FASTCNFG
DEVICE, HOSTS, and POLLTYPE Configuration for FASTPTCP on page 3-13. If
necessary, run FASTKCUT to generate the FASTKCON file, and restart the Spooler
device. (Depending on the device configuration, the device might restart automatically.)
62
proc-name
is the process name of the FASTPTCP process.
device-name
is the Spooler device name.
Cause. FASTCNFG or FASTKCON was changed while a F
ASTPTCP process was
active, and the print process had already printed one or more jobs for the device and
had started another print job.
Effect. No printing occurs, the Spooler job is requeued
, and the Spooler device is
placed offline with error 66.
Recovery. Restart the Spooler device. (Depending on the device configuration, the
device might restart automatically.)
proc-name DEV: device-name not defined in FASTKCON/FASTCNFG
proc-name DEV: device-name FASTKCON/FASTCNFG has changed,
resetting device