Spooler FASTP Network Print Processes Manual
EMS Messages
Spooler FASTP Network Print Processes Manual — 427528-007
B - 51
FASTPTCP Event Messages
82
proc-name
is the process name of the FASTPTCP process.
device-name
is the Spooler device name.
define-name
is either =FASTKCON or =FASTCNFG.
file-err
is the file-system error returned. See the Guardian Procedure Errors and
Messages Manual for explanations of file-system errors.
cnfg-file
is the name of the FASTCNFG or FASTKCON file specified in the ADD DEFINE.
Cause. The specified FASTCNFG or FASTKCON file could not be opened due to a
file-system error.
Effect. No printing occurs, the Spooler job is requeued, and the Spooler device is
placed offline.
Recovery. If the wrong FASTCNFG or FASTKCON file is used, either correct the
DEFINE statement and restart the Spooler or correct the FASTCNFG= parameter in
the higher level FASTCNFG file.
If a FASTCNFG file does not exist (error 1
1), create one.
For error 12 (file in use), make sur
e the FASTCNFG file is not in use by EDIT or
another process.
For error 48, adjust the file security or restart the Spooler from another user ID.
After the configuration file access is corrected, rest
art the Spooler device. (Depending
on the device configuration, the device might restart automatically.)
proc-name DEV: device-name Cannot OPEN Define define-name
Error file-err, File cnfg-file