Spooler FASTP Network Print Processes Manual
EMS Messages
Spooler FASTP Network Print Processes Manual — 427528-007
B - 78
FASTP EMS 512 Text Messages
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
error-number
is the socket error that occurred. See the Tandem NonStop TCP/IP and IPX/SPX
Programming Manual for explanations of socket errors.
operation
is a text description of the socket operation.
error-text
is a text description for some common error codes or the following text:
(error text not available).
Cause. This message only applies to FASTPTCP. FASTPTCP encountered a TCP/IP
socket error. This message is usually accompanied by another message; refer to the
documentation for that message for details.
Effect. Varies based on the operation and error. Possible effects include the following:
•
The job might have printed partially or not at all.
•
The print might be requeued to the Spooler.
•
The Spooler device might be placed offline.
Recovery. Varies based on the operation and error
. Possible recovery actions include
the following:
•
Correct the network error.
•
Ensure the device is online and is not out of paper.
•
Restart the Spooler device. (Depending on the device configuration, the device
might restart automatically.)
proc-num DEV: device-name Error: error-num on TCP/IP
operation = error-text