Spooler FASTP Network Print Processes Manual

EMS Messages
Spooler FASTP Network Print Processes Manual 427528-007
B - 78
FASTP EMS 512 Text Messages
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
error-number
is the socket error that occurred. See the Tandem NonStop TCP/IP and IPX/SPX
Programming Manual for explanations of socket errors.
operation
is a text description of the socket operation.
error-text
is a text description for some common error codes or the following text:
(error text not available).
Cause. This message only applies to FASTPTCP. FASTPTCP encountered a TCP/IP
socket error. This message is usually accompanied by another message; refer to the
documentation for that message for details.
Effect. Varies based on the operation and error. Possible effects include the following:
The job might have printed partially or not at all.
The print might be requeued to the Spooler.
The Spooler device might be placed offline.
Recovery. Varies based on the operation and error
. Possible recovery actions include
the following:
Correct the network error.
Ensure the device is online and is not out of paper.
Restart the Spooler device. (Depending on the device configuration, the device
might restart automatically.)
proc-num DEV: device-name Error: error-num on TCP/IP
operation = error-text