Spooler FASTP Network Print Processes Manual

EMS Messages
Spooler FASTP Network Print Processes Manual 427528-007
B - 85
FASTP EMS 512 Text Messages
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
status
is the Xerox formatter status. For a list of the Xerox formatter status values and the
actions FASTPXNS performs in response, see Table 7-3 on page 7-18.
Cause. This message applies to FASTPXNS only and reports the status of the
formatter component of the Xerox printing system. By default, FASTPXNS only reports
formatter status when it is likely to impair the successful delivery of Spooler jobs.
However, if DEV PARM 2 is set in Spoolcom, FASTPXNS reports the Xerox formatter
status regardless.
Effect. See Table 7-3 on page 7-18.
Recovery. See Table 7-3 on page 7-18.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
port-name
is the TLAM port used by FASTPXNS to extract printer responses.
%nnnnnn
is the error code returned by the TLAM ZL2S_GET_SDU procedure.
Cause. This message applies to F
ASTPXNS only. FASTPXNS could not decode a
buffer received from TLAM.
Effect. The buffer is discarded and FASTPXNS waits for the next TLAM response.
proc-num DEV: device-name Formatter Status: status
proc-num DEV: device-name port-name Get SDU Error %nnnnnn