Spooler FASTP Network Print Processes Manual
EMS Messages
Spooler FASTP Network Print Processes Manual — 427528-007
B - 89
FASTP EMS 512 Text Messages
Cause. This message applies to FASTPXNS only. FASTPXNS is about to send an
invalid XNS Courier parameter. Courier is a protocol used to establish the environment
before printing and after printing.
Effect. The device is placed offline.
Recovery. If the error persists, contact your service provider as described in
Troubleshooting and Reporting Problems on page 8-1.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
hex-data
is a hexadecimal display of some of the data received from the printer.
Cause. This message applies to FASTPTCP only. FASTPTCP has been configured
with DRAIN=YES, and DRAINLOG=YES received input data from the printer.
Effect. This message is informational only.
Recovery. If no other errors occur, no action is needed. You can change
DRAINLOG=NO to eliminate this message. For more information, see the description
of the message: proc-name DEV: device-name Invalid Do Timing Mark
reply: hex-data.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
%nnnnnn
is the octal code for the internal error.
proc-num DEV: device-name Inbound data received by DRAIN
option - starting with: hex-data
proc-num DEV: device-name Internal Error %nnnnnn From Format
SDU header