Spooler FASTP Network Print Processes Manual

EMS Messages
Spooler FASTP Network Print Processes Manual 427528-007
B - 90
FASTP EMS 512 Text Messages
Cause. This message applies to FASTPXNS only. FASTPXNS encountered the
specified error while assembling the Ethernet header prior to sending a buffer to TLAM.
This error indicates a probable logic error within FASTPXNS.
Effect. The device is place offline.
Recovery. If the error persists, contact your service provider as described in
Troubleshooting and Reporting Problems on page 8-1.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
fastcnfg
is the FASTCNFG file name.
Cause. This message applies to FASTPX25 only. The X25NUA value specified for the
device in the FASTCNFG file is invalid.
Effect. The device is placed offline.
Recovery. Correct the X25NUA parameter in the specified FASTCNFG file, and
restart the Spooler device. (Depending on the device configuration, the device might
restart automatically.)
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
hex-data
is a hexadecimal display of some of the dat
a received from the printer.
proc-num DEV: device-name Invalid address in fastcnfg
proc-num DEV: device-name Invalid Do Timing Mark reply:
hex-data