Spooler FASTP Network Print Processes Manual

EMS Messages
Spooler FASTP Network Print Processes Manual 427528-007
B - 93
FASTP EMS 512 Text Messages
Effect. The device is placed offline.
Recovery. Either change the CONTYPE configuration so that it matches that of the
actual device or specify another device name that actually is associated with an
X25AM subdevice.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
nn
is the actual IOP type associated with the device name.
Cause. The specified device name was configured as CONTYPE=X25, but the IOP
associated with this device name is not X25AM (61).
Effect. The device is placed offline.
Recovery. Either change the CONTYPE configuration so that it matches that of the
IOP associated with the device, or specify another device name that actually is
associated with an X25AM subdevice.
512
proc-num
is the process number (CPU, PIN) of the FASTPTCP process.
device-name
is the Spooler device name.
job-num
is the job number.
file-name
is the name of the Spooler Colle
ctor data file.
proc-num DEV: device-name is not owned by X25AM Type = nn
proc-num DEV: device-name Job: job-num, Cannot OPEN file-name
Err: file-err