Spooler FASTP Network Print Processes Manual
EMS Messages
Spooler FASTP Network Print Processes Manual — 427528-007
B - 119
FASTP EMS 512 Text Messages
Cause. FASTPX25 could not insert the specified token into the SPI buffer using the
SSPUTTKN procedure. FASTPX25 uses this information to verify that the X25AM SU
is configured to use an SVC.
Effect. If FASTPX25 cannot obtain this information, it assumes that the SU uses an
SVC and attempts to print.
Recovery. If your print job is unsuccessful, check the following:
•
Ensure that the SCP process is running correctly.
•
If your installation doesn’t use $ZNET, check that you have added a DEFINE=SCP
statement before running the Spooler Supervisor.
If the error persists, contact your service provider as described in Troubleshooting and
Reporting Problems on page 8-1.
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
status
is the Xerox spooler status. For a list of the Xerox spooler status values and the
actions FASTPXNS performs in response, see Table 7-2 on page 7-17.
Cause. This message applies to FASTPXNS only and report
s the status of the spooler
component of the Xerox printing system. By default, FASTPXNS only reports spooler
status when it is likely to impair the successful delivery of Spooler jobs. However, if
DEV PARM 2 is set on in Spoolcom, FASTPXNS reports the Xerox spooler status
regardless.
Effect. See Table 7-2 on page 7-17.
Recovery. See Table
7-2 on page 7-17.
proc-num DEV: device-name Spooler Status: status