Spooler FASTP Network Print Processes Manual

EMS Messages
Spooler FASTP Network Print Processes Manual 427528-007
B - 123
FASTP EMS 512 Text Messages
Recovery. Reduce the entries in the SVCLIST to 256 or fewer entries and restart the
Spooler device. (Depending on the device configuration, the device might restart
automatically.)
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
fastcnfg
is the FASTCNFG file name.
Cause. This message applies to FASTPX25 only. Both the SVCLIST and
SVCMACRO attributes were specified in the FASTCNFG file for this device. You
cannot specify both of these attributes for the same device.
Effect. The device is placed offline.
Recovery. Remove either the SVCLIST or SVCMACRO attribute from the FASTCNFG
file and restart the Spooler device. (Depending on the device configuration, the device
might restart automatically.)
512
proc-num
is the process number (CPU, PIN) of the process.
device-name
is the Spooler device name.
temp-name
is the name of the temporary disk file, either from the F
ASTCNFG parameter
TEMPFILE or a default name.
proc-num DEV: device-name SVCLIST - SVCMACRO conflict in
fastcnfg
proc-num DEV: device-name Tempfile temp-name operation
Err: file-err [Ext:ext Max: max]