SQL/MX 3.2 Messages Manual (H06.25+, J06.14+)
Executor Sort and Scratch File I/O Messages (10000
through 10199)
HP NonStop SQL/MX Release 3.2 Messages Manual—691121-001
12-2
Executor Sort Messages
SQL 10006
Cause. A previous I/O failed during a nowaited scratch file I/O operation.
Effect. The operation fails.
Recovery. Do not attempt recovery. Contact your service provider.
SQL 10007
Cause. An I/O error occurred during a scratch file I/O operation.
Effect. The operation fails.
Recovery. Contact your service provider.
SQL 10008
Cause. The caller of sort specified an invalid sort algorithm.
Effect. The operation fails.
Recovery. Do not attempt recovery. Contact your service provider.
SQL 10010
Cause. The scratch run on the disk does not belong to any scratch block on the disk.
Effect. The operation fails.
Recovery. Do not attempt recovery. Contact your service provider.
SQL 10011
Where system error is the error returned.
Cause. An I/O error occurred during a scratch file I/O operation.
10006 A previous IO to a scratch file failed.
10007 Sort failed while writing to a scratch file with error
system error.
10008 Invalid sort algorithm selected.
10010 Sort run number is invalid.
10011 Sort failed while reading a scratch file with error
system error.