SQL/MX Connectivity Service Manual for SQL/MX Release 3.2 (H06.25+, J06.14+)
-PR port-range
specifies the number of ports that can be used simultaneously for connections to
the MXCS association server (including the starting port number). The minimum
requirement is 3 port numbers; the default is 250. The port range specified must
not conflict with port numbers used by other applications.
-I
specifies the interactive startup mode for the association server. When this mode
is specified, the association server is created in the STOPPED state and you must
use NSM/web or the interactive MXCI interface to enable it. The default is the
non-interactive state.
-E detail-level
0 Minimum, critical events only
1 Informational events
2 Internal state transition events
The default value is 0.
-RMC alternate-collector-name
specifies the name of the alternate EMS collector to be used for resource statistics
generated by MXCS. If option [-RMC alternate-collector-name] is not provided,
MXCS Server Trace sends trace messages to the primary EMS collector. You must
start the alternate collector before starting MXCS. If resource statistics is enabled
but the alternate collector is not started, an error message is logged to the default
collector ($0). See “Configuring Statistics Collection” (page 40).
-TMC alternate-collector-name
specifies the name of the alternate EMS collector to be used for server tracing
generated by MXCS. If option [-TMC alternate-collector-name] is not provided,
MXCS Server Trace sends trace messages to the primary EMS collector. You must
start the alternate collector before starting MXCS. If server tracing is enabled but
the alternate collector is not started, an error message is logged to the default
collector ($0). See “Configuring Server Tracing” (page 46).
Additional Information
• After the MXCS service is started, you use NSM/web or MXCI to enable the MXCS service.
• Only the parameters described here are valid. The IN, OUT, stdin, stdout, or stderr parameters
are not recognized by MXCS.
• If you specify an invalid value for any parameter, the default value is used (if available). If
the parameter has no default value, MXOAS terminates with an error.
• When the MXCS service is started, it then starts the other MXCS server components, as specified
in the configuration. When the server components are started and available, the MXCS service
is ready to accept incoming connections.
22 Installing, Starting, and Uninstalling MXCS