TMF Application Programmer's Guide (H06.06+, J06.03+)

TMF ARLIB2 Audit-Reading Procedures
HP NonStop TMF Application Programmers Guide540139-009
5-52
ARFETCHMXAFTERDATA2
If the return code is ARE-BUFFER-TOO-SMALL, this parameter contains the
minimum length necessary for the image-buffer in bytes (adjusted to mod 8).
For all other return-code values this parameter contains zero.
sub-system output, optional
INT .EXT:ref:1
is a returned value valid only when return-code equals ARE-INTERNAL-ERROR
(-1000), in which case this value reports the subsystem that returned the error.
Table 5-4 describes the subsystem codes.
ar-error output, optional
INT .EXT:ref:1
is a returned value valid only when return-code equals ARE-INTERNAL-ERROR
(-1000), in which case the value indicates the specific error. Table 5-5 describes
the error codes.
Considerations
The optional parameters sub-system and ar-error must be passed in pairs.
You must pass either both the parameters or none.