TS/MP Pathsend and Server Programming Manual (H06.05+, J06.03+)
This parameter is required.
inputmaximum-reply-len
INT:value
is the maximum number of bytes that the reply message from the server class can contain. The range
of acceptable values is 0 through 32767 bytes.
No more than maximum-reply-len bytes of the actual reply are placed into message-buffer upon
successful completion of a send.
It is not an error if the server replies with a byte count not equal to the maximumreply-len value
specified by the requester in the call to this procedure. If the server replies with a byte count greater
than the maximum-reply-len value, the actual bytes transferred are truncated to
maximum-reply-len.
This parameter is required.
outputactual-reply-len
INT:ref:EXT:1
returns a count of the number of bytes returned in the server process reply. This parameter is for
waited I/O only and can be omitted for nowait I/O. The return value of this parameter is 0 if nowait
I/O is used. For nowait I/O, the actual reply length is returned by AWAITIOX.
inputtimeout
INT(32):value
specifies the maximum amount of time, in hundredths of a second, that the LINKMON process waits
for the completion of this send. This value must be either -1D or a value greater than 0D. The default
is -1D (wait indefinitely).
If there is an outstanding I/O operation to a server process when a SERVERCLASS_SEND_ operation
times out, the I/O operation is canceled.
For information about timeout for waited and nowait operations, see “Timeout Considerations for
Pathsend Programming” (page 106).
For more information on Pathsend error 904 and file-system error 40, see “Server Timeout” (page 106).
inputflags
INT:value
flags.<15>
with a value of 1 indicates that this operation is to be performed nowait. A value of 0 indicates
that this operation is to be performed waited. The default is 0.
flags.<0:14>
must be 0.
NOTE: For information on setting flag 9 for TS/MP 2.3 and later versions, see “Bridging Pathsend
API into Pathway Domain” (page 108).
outputscsend-op-num
INT:ref:EXT:1
returns the server-class send operation number. You can use the server-class send operation number
in place of the file number parameter in calls to CANCEL, CANCELREQ, and AWAITIOX for nowait
sends, and in calls to FILEINFO for waited and nowait sends, to indicate that the calls refer to
server-class send operations. The value of scsend-op-num is determined on the first successfully
94 Pathsend Procedure Call Reference