G06.24 ReadMe
TCPIPv6 Monitor process stopped by operator.
Cause: The operator or system administrator stopped the monitor
process in the NonStop TCP/IPv6 subsystem.
Effect: All the network activity through the monitor in that
processor ceases.
Recovery: Because the NonStop TCP/IPv6 subsystem was brought down by
the operator or system administrator, no further action is
recommended.
13 (Critical Event)
Subnet subnet LIF Filter register timeout.
Cause: The NonStop TCP/IPv6 subsystem is waiting for a filter
registration to complete.
Effect: The NonStop TCP/IPv6 subsystem will attempt to register the
filter again. If this problem continues, the LIF becomes inaccessible.
Recovery: If this event continues after another attempt has been
made to register the filter, abort and restart the LIF.
14 (Critical Event)
LIF lif-name access unavailable from CPU cpu-num.
Cause: The NonStop TCP/IPv6 subsystem cannot access the LIF.
Effect: The LIF configured in the NonStop TCP/IPv6 subsystem
continues to be inaccessible until the problem is resolved.
Recovery: Make sure that the LIF is accessible from the processor
where the event occurred.
15 (Critical Event)
Unknown Device lif-name.
Cause: The device name specified for configuring the subnet does not
exist.
Effect: The LIF configured for the NonStop TCP/IPv6 subsystem is
not accessible until the problem is resolved.
Recovery: Make sure that the LIF is configured in the SLSA subsystem.
16 (Critical Event)
Device lif-name Returned a NULL MAC Address.
Cause: The SLSA subsystem returned a NULL MAC address to the NonStop
TCP/IPv6 subsystem when NonStop TCP/IPv6 tried to obtain the MAC
address for the interface.
Effect: The LIF configured for the NonStop TCP/IPv6 subsystem is
inaccessible until the problem is resolved
Recovery: Make sure that the LIF is properly configured in the SLSA
subsystem.
17 (Critical Event)
name: Filter Register For IP Address ip-addr Failed,
Error= err-code, Filter Type = type, Local Port = port
Page
12
of
21