G06.24 ReadMe
object, perform a Start Monitoring [Maintenance Switch or UPS]
action.
Workaround
To avoid the alarm, perform a Stop Monitoring action on the device
before changing the username or password. After the change is made,
perform the Start Monitoring [Maintenance Switch or UPS] action,
from the Monitored Service LAN Devices object.
Solution 10-030924=9912
Attempting to Power Off the group in which certain OSM processes are
running (either the RALPRVD selected by the CIMOM to execute the
action, or both the primary and backup CIMOM processes) results in
the action status remaining "In Progress" and possible loss of the
OSM Service Connection session.
Recovery
Establish a new OSM Service Connection session (if original session
is lost), try a Rediscover action on the group or repeat the Power
Off action on the group (the OSM processes will automatically
start-up in a processor in another group).
Workaround
Halt the individual processors in the group (it's best to wait about
ten minutes between the two) before powering off the group (the OSM
processes will automatically switch to another processor).
OSM Web-Based Suite (T2751)
Solution 10-040813-8808
When an FCSA is inserted or replaced, the adapter might not be
displayed in Physical view (in the View pane).
Recovery
In the Tree pane, click on an object in another group, then back to
the group containing the FCSA, the FCSA should now appear in the
Physical view.
Workaround
None.
Solution 10-040816-8859
When a G4SA is powered off using the OSM Service Connection, a 500
series error is displayed in place of the Physical view in the View
pane.
Recovery
Right-click on the OSM View pane and select Refresh (do not select
Refresh from the Internet Explorer View menu). The Physical view
should now be restored in the View pane.
Workaround
None.
Solution 10-040813-8804
When establishing an OSM Service Connection session, two Internet
Explorer browser windows are launched: the window in which the OSM
Service Connection appears and a secondary browser window displaying
the message "OSM Loaded... You may now close this window" is also
Page