G06.24 ReadMe
STOP DEVICE #
ALTER DEVICE #, LOCALPOOLPAGES (where n is < 53)
START DEV #
Workaround
Configure the TR3271 device with the modifier LOCALPOOLPAGES value
less than or equal to 52.
o WANASYNC-RDCONT (T0587)
Solution 10-030402-5260
Pressing the BREAK key continually in response to READ requests will
result in a dump of the SWAN CLIP on which WANASYNC-RDCONT is
configured. A dump file is created in the $SYSTEM.ZWANDUMP file.
Recovery
The WANASYNC-RDCONT lines recover once the CLIP dump is complete.
Workaround
None.
Errata
----------------------------------------------------------------------
---Run the INSTALL^TEMPLATES Macro---
The procedure for installing EMS templates in Appendix A (page A-7)
and Appendix B (page B-14) of the G06.24 Software Installation and
Upgrade Guide should be revised based on Genesis solution
10-040824-9202.
Since the G06.10 RVU, if there is a resident template file in any of
the input subvolumes, the INSTALL^TEMPLATES macro displays this error:
Invalid nonresident template file -- not key sequenced:
$SYSTEM.ZTEMPL.NEWRES
*** INSTALL^TEMPLATES: Terminated due to error ***
HP recommends that you designate another subvolume (for example,
$SYSTEM.TEMPLATE) to contain the output from INSTALL^TEMPLATES. When
you specify this location, a non-resident template file will not be
present in ZTEMPL, and the error will not appear.
The revised procedure for correctly installing the templates:
1. Load the install^templates macro:
tacl> volume $system.zinsaids
tacl> load /keep 1/ taclmacs
2. Choose a location on $system to keep updated template files:
tacl>volume $system.template
3. Rename any existing templates:
tacl> rename newres, oldres
tacl> rename newnres, oldnres
Page