G06.25 ReadMe

G06.25 README
Copyright (C) 2005 Hewlett-Packard Development Company, L.P.
Protected as an unpublished work.
All rights reserved.
January 2005
The computer program listings, specifications, and documentation
herein are the property of Hewlett-Packard Development Company, L.P.
or a third-party supplier and shall not be reproduced, copied,
disclosed, or used in whole or in part for any reason without the
prior express written permission of Hewlett-Packard Development
Company, L.P.
This README (SUT) file contains information that was not available
at the time manuals, softdocs, and other release materials were
produced. This file contains only information pertinent to the
G06.25 Release Version Update (RVU).
See the online NonStop Technical Library (NTL) support collection for
the latest version of the README file.
----------------------------------------------------------------------
G06.25 README file
----------------------------------------------------------------------
o ATP6100 (T9337)
Solution 10-031125-1547
When a Setmode 13 is issued by the application with the second
parameter absent or set to 0 (both of which are incorrect), the
application read request will not complete and will hang.
Recovery
None.
Workaround
Change the application to ensure that the second parameter of
Setmode 13 is passed correctly. The second parameter should be the
configured END OF TEXT character.
o EMS BASE (T9631)
Solution 10-030812-8691
When the primary process stops/aborts and the backup process takes
over, the alternate key files (ZZSKnnnn) of the hardware logger
($ZLOG) are changed into ZZEKnnn.
Recovery
Stop $ZLOG from the TACL prompt (the AUTORESTART value should be
greater than 0). Being a generic process, $ZLOG will automatically
restart and behave normally. Commands to modify the autorestart
value are as follows:
>SCF ABORT PROC $ZZKRN.#TSM-ZLOG
>SCF INFO PROC $ZZKRN.#TSM-ZLOG,DETAIL
>ACF ALTER PROC $ZZKRN.#TSM-ZLOG,AUTORESTART ;
where n is an integer from 0 to 10.
>scf start proc $zzkrn.#tsm-zlog
Note that if the AUTORESTART value is equal to 0, the user must