G06.25 ReadMe

Recovery
None. However, Ignore the error message. The command wil have
successfully completed even though it generates this error.
Workaround
None.
o Measure (T9086)
Solution 10-040810-8690
The Measfh process will abend with Trap %2 if primary and secondary
extents are specified as 1024 or greater.
Recovery
None.
Workaround
Start a measurement with primary and secondary extents of less than
1024.
o NSK (T9050)
Solution 10-030805-8485
When a code breakpoint and memory access breakpoint (MAB) are
placed at the same address during a debug session, the session will
hang after it is resumed. The TACL STOP command will not stop the
process.
Recovery
None.
Workaround
Avoid setting MAB and code breakpoint at the same address.
o OSM Service Suite (T0682)
Solution 10-141028-1177
When a configured adapter in a particular slot is removed, and
another adapter of a different type is inserted into the same slot,
the OSM SC will display the new adapter type with the removed
adapter's configuration information.
Recovery
None.
Workaround
To replace an adapter with a new adapter, use the following
procedure:
1. Using SCF, delete the adapter to be removed.
2. Remove the adapter from the slot.
3. Insert the new adapter into the slot.
4. Using SCF, configure the new adapter.
Solution 10-041129-2256
When the "Loading Tree View" message is selected in the Tree View
pane of OSM Service Connection when the OSM Service Connection is
started, the Tree View pane stays blank and no objects are displayed.
Page
3