G06.26 ReadMe

None. However, Ignore the error message. The command wil have
successfully completed even though it generates this error.
Workaround
None.
o Measure (T9086)
Solution 10-040810-8690
The Measfh process will abend with Trap %2 if primary and secondary
extents are specified as 1024 or greater.
Recovery
None.
Workaround
Start a measurement with primary and secondary extents of less than
1024.
o NSK (T9050)
Solution 10-030805-8485
When a code breakpoint and memory access breakpoint (MAB) are
placed at the same address during a debug session, the session will
hang after it is resumed. The TACL STOP command will not stop the
process.
Recovery
None.
Workaround
Avoid setting MAB and code breakpoint at the same address.
o NSKCOM (T5838)
Solution 10-050317-5699
If a specified scratch volume is a JBOD/ESS disk, the disk process
causes the CPU to go to 100% busy when building SRL ZCLIPREL with
NLD. It stays in this loop indefinitely.
Recovery
None.
Workaround
Do not use a JBOD/ESS disk as a SCRATCH volume for a DSMSCM build.
o ONC RCP (T9566)
Solution 10-050223-4897
The RPC server abends when registering with PORTMAPPER if Logical
Network Partitions (LNPs) are configured on IPv6.
Recovery
Restart the server on a different transport provider where LNPs are
not configured.
Workaround
None.
Page
3
of
10