G06.26 ReadMe
o OSM Service Connection Suite (T0682)
Solution 10-050304-5301
No alarm is generated on the external disk for incorrectly
configurated SNDAs; for example, an external disk configured through
SNDA adapters that have been configured on X-fabric (Slots 51 & 53)
or Y-fabric (Slots 52 & 54).
Recovery
None.
Workaround
Insert the SNDA adapters such that primary and backup controllers
are on different ServerNet fabrics (X and Y).
o OSS NFS (T9628)
Solution 10-040728-8278
When an SCF NFS start server command is issued for a particular NFS
server, whose corresponding fileset is not in the STARTED state, the
following error is observed:
"NFS E-00012 Maximum Limit Exceeded: OLFC2 for "
Recovery
1. Start the respective filesets for the desired NFS server.
2. Bring down the NFS susbystsem.
3. Re-start the NFS subsystem.
Workaround
None.
o Safeguard (T9750)
Solution 10-041116-1788
Under the following conditions:
1. An object is added to Safeguard protection with the Access
Control List (ACL) that grants secondary ownership to a node
specific user.
2. The Node specific user tries to alter the ACL from the specific
node.
Objects having ACLs that grant secondary ownership to a user from a
specific node, cannot be managed by that user through SAFECOM from
the specified node. The following error message occurs:
*ERROR* RECORD FOR DISKFILE filename: SECURITY VIOLATION
Recovery
None.
Workaround
None.
o SMLOGVOL (T8472)
Solution 10-050301-5145
Under the following circumstances:
Page
4
of
10