G06.26 ReadMe

o TCP/IP TELSRV (T9553)
Solution 10-040630-7472
Under the following conditions, TELSERV may display garbled
characters:
1. TELSERV is running on a Conventional TCP/IP stack.
2. A terminal is opened in Tandem emulation mode.
3. On the same terminal, a static window is configured through SCF
for the TELSERV process with the CALLER6 attribute.
Recovery
Switch the terminal from Tandem emulation to VT100 and back to
Tandem emulation.
Workaround
None.
Solution 10-031009-0267
If the underlying transport agent (TCPSAM) is brought down while
TELSRV has at least one TELNET session established through the
transport agent, the TELSRV process will abend with the following
EMS message:
TELNET NO LONGER OPERATIONAL: REPLYX FAILED
Recovery
Restart the TELSRV process.
Workaround
None.
o TCP/IPv6 Subsystem (T1265)
Solution 10-041129-2262
STATS TCP6SAM does not display IPv6 statistics (all zeros are
displayed).
Recovery
None.
Workaround
Instead of issuing the STATS command on the SAM, use the STATS
command on the MON.
Solution 10-040212-3224
The SCF command:
ALTER MON *,ARPTIMER-REFRESHED ON
fails to set the ARPTIMER-REFRESHED parameter.
Recovery
None.
Workaround
None.
Page
7
of
10