G06.26 ReadMe
EMS Messages (003,008,009)
TRAPMUX Message 006
Bad EIO Status #222
Bad Interrupt Cause #120
Bad Interrupt Cause #140
Recovery
See that the application does not cancel the request before
receiving a response for it.
Workaround
None.
Solution 10-050216-4759
When there is a RTS-CTS delay setting in a modem, which when set
to zero or 50 milliseconds or less, the ENQ goes out immediately
after a connection is made. However, if the RTS-CTS setting is set
higher than 50 milliseconds or more, the outbound ENQ is delayed up
to seven seconds. This may cause an application problem.
Recovery
None.
Workaround
Configure the RTS-CTS delay in the modem to a value of 50
milliseconds or less.
o WANMGR (T1228)
Solution 10-040922-0009
If a large number of SCF ADD ADAPTER commands are issued from a
TACL script with no delays between the SCF ADD ADAPTER commands,
and the SAVEABEND attribute is set for the $ZZWAN process, many
saveabend files will be created in $SYSTEM.SYSTEM.
Recovery
None. Other than the many saveabend files created, there are no
other user consequences.
Workaround
None.
o XIO (T8374)
Solution 10-031121-1510
The following error:
MEAS 3403 Invalid descriptor
is seen when the LISTACTIVE command for subdevice 3 is executed in
the MEASCOM tool.
Recovery
None.
Workaround
Use the LIST command to retrieve information for modules having
subdevice number 3.