H06.03 Release Version Update Compendium

H06.03 Release Version Update Compendium540008-002
2-1
2 Operating System
The H06.03 RVU contains these operating system changes:
DCT Limits
NonStop Operating System Software
OSS Compiler Utilities
Standard POSIX Threads
DCT Limits
In H-series RVUs, the default limit on the number of entries in the destination control
table (DCT) is 65,536. The default limit in G-series RVUs remains 32,767.
For information on how to determine whether an application requires changes to
function correctly when presented with a DCT index that exceeds the limit, see Support
Note S03123A.
NonStop Operating System Software
Major areas of change in the NonStop operating system (T9050) include:
Process control
Debug services
Interrupt environment
Signals and traps
Initialization
G-threads and history APIs
Memory management changes to adapt to the memory architecture of the TNS/E
system and Itanium processors
Support for dynamic-link library (DLL)
Message system
New products:
NonStop OS Disk/Tape Boots (T2773)
OS Builder (T0431)
These products also have changes:
NonStop OS Utilities (T9070), reload and memory dump
Integrity NonStop NS-series servers header files
NonStop OS (T9050), Configuration Services (T6586), and Maintenance IOP
(T8171) now support the processor switch maintenance entity.