H06.03 Release Version Update Compendium
Application Development Products
H06.03 Release Version Update Compendium—540008-002
3-3
TNS Object Code Accelerator
•
New versions of RCVDUMP and RELOAD.
The RCVDUMP program (super-group or super ID only) has two new parameters
for H-series systems only, SLICE <sliceId> and PARALLEL.
°
The <sliceId> parameter indicates the NonStop Blade Element containing
the processor element (PE) that has to be dumped.
°
The PARALLEL option specifies that the dump is asymmetric (one PE is
dumped while the other PEs in that logical processor continue normal
operations).
RELOAD has a new option (for H-series systems only) called OMITSLICE. The
RELOAD program (super-group only) now also includes the option NOPRIME,
which is supported on both G-series and H-series systems.
For RCVDUMP and RELOAD syntax summaries, see Appendix A of the TACL
Reference Manual.
For new RCVDUMP and RELOAD error messages, see Appendix B of the TACL
Reference Manual.
•
These TACL built-in functions have been updated:
°
#NEWPROCESS allows 800 coded (TNS/E) file to run.
°
#FILEINFO gives information for 800 coded (TNS/E) file.
°
#DEVICEINFO built-in function mapping has been changed to
FILE_GETINFOLISTBYNAME_.
TNS Object Code Accelerator
The TNS Object Code Accelerator (OCA, T0448) is a program optimization tool that
processes a TNS object file and produces an accelerated file for a TNS/E system.
OCA enables you to run and improve the performance of programs that run on TNS/E
systems. The OCA optimizes TNS program files (compiled and bound object files) to
take advantage of TNS/E architecture.
Note. In software interfaces and messages, you might see:
•
The term slice, which is equivalent to the term NonStop Blade Element (NSBE). In
a future RVU, slice will be replaced with NonStop Blade Element, Blade Element,
or NSBE.
•
The term processor complex, which is equivalent to the term NonStop Blade
Complex (NSBC). In a future RVU, processor complex will be replaced with
NonStop Blade Complex, Blade Complex, or NSBC.