H06.04 ReadMe
This problem might occur when running Measure.
LIKELIHOOD:
Likely under heavy usage.
DIRECT IMPACT:
Processor halts
SIDE-EFFECTS:
None
WORKAROUND:
None
RECOVERY:
Reload the processor.
o TAPEPROCESS (T0021)
Solution 10-050817-0676
SYMPTOMS:
The primary processor of TAPEPROCESS halts with a %102200 halt code.
CONDITIONS:
The tape drive is connected to the NonStop NS-series system through
an IOMF2 cabinet.
LIKELIHOOD:
Likely
DIRECT IMPACT:
Loss of a single processor.
SIDE-EFFECTS:
None
WORKAROUND:
Connect SCSI tape drives to the NonStop NS-series system using the
FC-SCSI router.
RECOVERY:
Reload the failed processor.
o TNS/E COBOL (T0356)
Solution 10-051027-2227
SYMPTOMS:
The compiler issues an error message "Compiler logic error 0_4
[Failure 0]".
CONDITIONS:
The program must contain both of the following for the problem
to occur:
- A data item is described with PIC X or PIC 9 and USAGE DISPLAY
(that is, one character) and an OCCURS clause, where the data
item is (or is an element of a group that is) GLOBAL or EXTERNAL.
- A level-88 condition-name with more than one data value is listed
in its VALUE clause, and the condition-name is used at least
Page