H06.04 Software Installation and Upgrade Guide
Overview of Installing the H06.04 RVU
H06.04 Software Installation and Upgrade Guide—541607-001
1-17
Managing ServerNet Adapter Firmware
To update firmware for ServerNet adapters connected to legacy IOMF2 CRUs, see the
latest G-series Software Installation and Upgrade Guide.
To see if the ServerNet adapter firmware needs to be updated, navigate down the
OSM tree pane for FCSA and G4SA:
•
FCSA. The FCSA has two ports that allow connection to external, fibre-channel-
enabled devices. You might need to update these firmware files using either SCF
or OSM.
°
The flash boot firmware (T0630G06) contains version information about the
boot firmware located in the FCSA FLASH memory. The boot firmware runs on
every FCSA after power on and after hardware or firmware errors, and is re-
downloaded to initialize the adapter and to accept downloaded firmware from
the processor. The AAG SPR is available for this T number.
°
The flash firmware (T0612G06) contains version information about the
operational firmware located in the FCSA FLASH memory. Flash firmware runs
the FCSAs used for system load so that the processor boot millicode can read
the system-load disk.
Note. Before connecting a NonStop S-series system to an Integrity NonStop NS-series
system through legacy I/O, you must first update the firmware for both the S-series Gigabit 4-
port ServerNet adapter (G4SA) and the Fibre Channel ServerNet adapter (FCSA). Firmware
for both the G4SA and FCSA adapters used for S-series systems is not initially compatible with
Integrity NonStop NS-series systems.
If you have a NonStop S-series system that is connected to the Integrity NonStop NS-series
system via Expand or ServerNet Clusters, you do not need to initialize the G4SA or FCSA
firmware.
VST013.vsd