H06.05 Software Installation and Upgrade Guide

Overview of Installing the H06.05 RVU
H06.05 Software Installation and Upgrade Guide541762-003
1-28
SMF
SMF
Beginning in the H06.05 RVU, SMFINTRFCE (T0063) is merged into the SMF (T8472)
product. The merging of these T-numbers can cause a problem if you are installing the
SMF bundle (T8472H01^ACW or later) on a pre-H06.05 system without installing the
entire SUT. (The problem does not occur if you are installing the entire G06.28 or later
SUT.)
The problem occurs because the merged version of SMF and the existing T0063
component in your current (pre-H06.05) RVU both attempt to place the file ZSMFC in
the ZSPIDEF subvolume. This attempt results in a “duplicate file was found” error
during the DSM/SCM installation of T8472H01^ACW or later.
You can avoid this problem by manually removing T0063 before the upgrade, as
follows: During the upgrade operation, DSM/SCM detects the duplicate SMF
components and generates a message indicating that T0063 is already present in your
current configuration. DSM/SCM then prompts you to either retain or remove it.
Respond to this prompt by requesting removal of T0063.
Backup/Restore 2
Beginning in the H06.05 RVU, the Backup/Restore 2 products are merged into a single
T-number, T0744. When you use DSM/SCM to install the new SUT, the following
screen will appear, prompting you to select the products to retain:
Since the new T-number T0744 is replacing the previous T27nn T-numbers, click
Continue without selecting any of the T27nn T-numbers. DSM/SCM will remove those
T-numbers from your configuration and install T0744.
vst750.vsd