H06.05.01 ReadMe

SIDE-EFFECTS:
None
WORKAROUND / RECOVERY:
Perform the cable check action as suggested in the alarm.
o Complex Manager AP (CMAP, T0777)
Solution 10-060206-4279
SYMPTOMS:
Processor halt occurs with haltcode %5570.
CONDITIONS:
This problem might occur when two strands are miscabled to
LSUs on a running system.
LIKELIHOOD:
Very likely, when more than one strand is miscabled.
DIRECT IMPACT:
Processor halt
SIDE-EFFECTS:
None.
WORKAROUND:
Correct the cabling problem and reload the processor.
RECOVERY:
Reload the processor.
o Complex Manager AP (CMAP, T0777)
Solution 10-060131-4173
SYMPTOMS:
Processor halt occurs with haltcode %5570.
CONDITIONS:
This problem occurs when the system has faulty blade hardware and
firmware update goes on to reload processors.
LIKELIHOOD:
Undetermined.
DIRECT IMPACT:
Processor halt
SIDE-EFFECTS:
None
WORKAROUND:
Replace the blade hardware that has a problem before a system load
or reload.
RECOVERY:
Reload a processor.