Managing ServerNet Adapter Firmware
°
The flash firmware (T0612G06) contains version information about the
operational firmware located in the FCSA FLASH memory. Flash firmware runs
the FCSAs used for system load so that the processor boot millicode can read
the system-load disk.
°
RAM firmware: Operational firmware is downloaded to the FCSA when you
issue the first START DISK command to the first disk drive in the fibre-channel
loop.
°
Use the OSM Service Connection to check the FCSA’s firmware version and
update the firmware, if needed. If the Compare State shows Down-rev, update
the firmware. The following example shows that the firmware is at an earlier
version and needs to be updated:
•
G4SA. The OSM Service Connection displays G4SA firmware attributes and action
under the G4SA SAC object. To check or update G4SA firmware, locate and
expand the G4SA, then select its subcomponent G4SA SAC object. In the
following example, the firmware attributes show that the current firmware Version is
the same as the available Default File Version; no update is necessary. If the
Compare State was Down-rev, you would use the Firmware Update action to
update the firmware: