H06.07 Release Version Update Compendium
H06.07 Release Version Update Compendium—543439-001
6-1
6 Manageability Products
The H06.07 RVU contains new features for these manageability products:
•
Measure
•
OSM
•
Safeguard
•
SPI
Measure
Measure introduces the MEASFT utility, which splits a measurement data file into
multiple data files, according to user-specified criteria such as entity type or CPU.
Measurement configuration, start/stop records, and any applicable journal data are
written to each of the resultant files. The ability to split the measurement data into
multiple files allows the user to configure measurements that, in earlier product
versions, might have produced data files too large for the MEASCOM utility to process.
MEASFT defines three commands:
•
The SPLIT command splits a measurement data file according to specified criteria.
It can also create a new data file with selected records from the original data file.
•
The INFO command provides data about how much space in an existing data file is
associated with each entity type and with each CPU. This information can be used
to determine what the split criteria should be.
•
The HELP command displays the correct syntax for the specified MEASFT
command.
OSM
The new version of the NonStop Open System Management (OSM) Interface module
redundant power-scrub test provides independent battery testing and an extended load
test for the bulk power supplies. With this new version of the power-scrub test, the
redundant power scrub action can take up to 25 minutes to complete.
The ability of the new battery scrub to detect weak or failed batteries is significantly
enhanced. For systems with many old batteries (over 5 years old), the battery scrub
might call out multiple batteries for replacement.
Installation and Configuration
•
To use the power-scrub feature, you must install T0682H02^AAU (delivered with
the H06.07 RVU) or later for OSM.
•
To select the new power-scrub version, add this line in
$SYSTEM.ZSERVICE.OSMCONF: