Updating ME Firmware
Table 1-1 shows the current ME firmware information for both processor switches and
IOAMS:
The AAH SPR is available for the Maintenance Entity firmware. This SPR lifts a
restriction for IOAME modules connected to S-series enclosures when T1089ABR
firmware has been installed on the S-series processors.
For the Integrity NonStop NS5000 and Integrity NonStop NS16000 systems only:
Use the OSM Service Connection to update the ME firmware for processor switches.
1. Locate the ServerNet Switch Board on one Internal ServerNet Fabric (in the tree
pane, select System > Fabric Group > Internal ServerNet Fabric > Processor
Switch > ServerNet Switch Board).
2. Right-click the ServerNet Switch Board object and select Actions.
3. In the Actions dialog box, select ME Firmware Update and click Perform Action.
4. Monitor the update.
5. Repeat for the processor switch on the other Internal ServerNet Fabric.
To use the OSM Service Connection to update the ME firmware for each IOAM:
1. Locate the ServerNet Switch Board on one IOAM (in the tree pane, select System
> Group > IOAM Enclosure > IOAM > ServerNet Switch Board).
Table 1-1. Maintenance Entity (ME) Firmware
Product
Number Description Host FRU
Disk File
Name
Default
Location
Related
Information
T2805A01^AAI Maintenance
Entity (ME)
firmware (see
Note below)
ServerNet
Switch Board
(IOAM and
processor
switch)
M2805 SYSnn
subvolume
NonStop NS-Series
Hardware
Installation Manual
and OSM online
help
Caution. Ensure that the system is running the new H06.07 RVU before starting this
procedure.
Caution for ME FPGA. You should not use the Multi-Resource Actions dialog (in the OSM
Service Connection) to update ME FPGA simultaneously on both fabrics, or a system outage
might occur.
Caution for ME FW. You should not use the Multi-Resource Actions dialog (in the OSM
Service Connection) to update ME FW simultaneously on both fabrics, or a system outage
might occur.