H06.07 Software Installation and Upgrade Guide

Overview of Installing the H06.07 RVU
H06.07 Software Installation and Upgrade Guide543449-001
1-22
Managing SWAN and SWAN 2 Concentrator
Firmware
Managing SWAN and SWAN 2 Concentrator Firmware
Both SWAN and SWAN2 are supported in H-series RVUs and OSM is used to update
the firmware. SCF can also be used. For details on updating firmware, see
Appendix C, Updating SWAN Concentrator CLIP Firmware.
Table 1-5 lists the firmware for ServerNet SWAN concentrators.
Table 1-5. Updateable Firmware for ServerNet WAN (SWAN and SWAN 2)
Concentrators
Managing NonStop Cluster Switch Firmware
To monitor and manage a ServerNet Cluster product configured with 6780 switches,
use either the OSM Service Connection or SCF commands. See the ServerNet Cluster
6780 Operations Guide for more information.
For information on required software, installation, migration, and fallback procedures,
see the ServerNet Cluster 6780 Planning and Installation Guide.
Table 1-6 on page 1-23 lists the product number and updateable firmware information
for the cluster switch. Check with Scout for the latest SPRs.
Caution. For H-series platforms, you must upgrade T0287 (Halted State Services) to
T0287AAD before attempting to upgrade T0630 (FCSA flash boot firmware) to the
T0630G06^AAJ revision level. If you update the FCSA flash boot firmware without first
updating HSS, you will be unable to do a system load.
Product
Number Description
Host
CRU/FRU
Disk File
Name
Default
Location Tool
Related
Information
T7953AAN SWAN
Kernel
firmware
SWAN
concentrato
r CLIPs
C7953P00 CSSnn
subvolume
SCF;
OSM SC
SWAN
Concentrator
Installation and
Support Guide