Managing Firmware in a NonStop Blade Complex
3. Repeat Steps 1 and 2 for the other NonStop Blade Complexes.
b. Halt and then power cycle all processors:
1. Using OSM Low-Level Link, halt all the logical processors in the system.
2. Power cycle all processors as follows:
a. Log on to the OSM Low-Level Link.
b. On the tool bar, click System Discovery.
c. In the Management Window, double-click the system button (labeled
with the system name).
d. Right-click the GRP-400 button.
e. Select the Actions option.
f. From the GRP-400 actions list, select Power Cycle All Processors.
g. Click Perform Action.
h. Click OK when asked “Are you sure you want to do a Power Cycle All
Processors?”
i. When the Action Status box confirms that the power cycle has
successfully completed, close the dialog box.
3. Load (coldload) the system with the H06.08 RVU.
c. Update NonStop Blade Complex (NSBC) firmware on the other flash, as
follows:
1. Using the OSM Service Connection and the Blade Complex Firmware
Update guided procedure, complete the dialog boxes and update the
shadow firmware on each NonStop Blade Element.
2. Using the Switch Blade Element Firmware Images dialog box, select NO.
3. Repeat Steps 1 and 2 for the other NonStop Blade Complexes.
Note. It should take approximately five minutes for all processors to complete
Power On initialization.
Note. OSM will preselect all the firmware that it detects as down-rev.
Note. Update all NonStop Blade Elements in the complex at this time.