c. Reset the NonStop Blade Elements one at a time. Wait for each NonStop
Blade Element to be reintegrated before proceeding. Use the OSM Service
Connection Blade Element Reset Action to reset the NonStop Blade Element.
The shadow firmware image that has been updated is now the running flash
image. The previous running image is now the shadow image.
d. Repeat steps a. through c. to update the new shadow image on all NonStop
Blade Elements or one NonStop Blade Element at a time until all the NonStop
Blade Elements are done.
e. Repeat steps a. through d. for the other NonStop Blade Complexes.
Note: HP recommends that you reset and reintegrate each NonStop Blade Element
one at a time. (The Reset action power cycles the NonStop Blade Element.) Resetting
all NonStop Blade Elements at the same time will take four processors offline.
Do not manually power cycle the processors. Doing so will leave the NonStop Blade