H06.09 Software Installation and Upgrade Guide
Overview of Installing the H06.09 RVU
H06.09 Software Installation and Upgrade Guide—544316-002
1-11
Managing Maintenance Entity Firmware for
Processor Switch and I/O Adapter Module (IOAM)
For the Integrity NonStop NS5000 and Integrity NonStop NS16000 systems only:
Use the OSM Service Connection to update the ME firmware for processor switches.
1. Locate the ServerNet Switch Board on one Internal ServerNet Fabric (in the tree
pane, select System > Fabric Group > Internal ServerNet Fabric > Processor
Switch > ServerNet Switch Board).
2. Right-click the ServerNet Switch Board object and select Actions.
3. In the Actions dialog box, select ME Firmware Update and click Perform Action.
4. Monitor the update.
5. Repeat for the processor switch on the other Internal ServerNet Fabric.
To use the OSM Service Connection to update the ME firmware for each IOAM:
1. Locate the ServerNet Switch Board on one IOAM (in the tree pane, select System
> Group > IOAM Enclosure > IOAM > ServerNet Switch Board).
2. Right-click the ServerNet Switch Board object and select Actions.
3. In the Actions dialog box, select ME Firmware Update and click Perform Action.
4. Monitor the update.
5. Repeat for the processor switch on the other Internal ServerNet Fabric.
You can also check and update ME firmware using the OSM Low-Level Link. For more
information, see the OSM Low-Level Link online help.
For the Integrity NonStop NS1000 and Integrity NonStop NS14000 systems only:
Use the OSM Service Connection to update the ME firmware for processor switches.
1. Locate the ServerNet Switch Board on one Internal ServerNet Fabric (in the tree
pane, select System > Fabric Group > IOAM Enclosure > ServerNet Switch
Board).
2. Right-click the ServerNet Switch Board object and select Actions.
3. In the Actions dialog box, select ME Firmware Update and click Perform Action.
4. Monitor the update.
Caution for ME FPGA. You should not use the Multi-Resource Actions dialog (in the OSM
Service Connection) to update ME FPGA simultaneously on both fabrics, or a system outage
might occur.
Caution for ME FW. You should not use the Multi-Resource Actions dialog (in the OSM
Service Connection) to update ME FW simultaneously on both fabrics, or a system outage
might occur.
Note. T2805A01^AAF or later is required for the Integrity NonStop NS1000 and Integrity
NonStop NS14000 systems.