H06.11 Software Installation and Upgrade Guide

3) Reset the NonStop Blade Elements complex by complex.
4) Repeat steps 1 through 3 for the other NonStop Blade Complexes.
b. Update NonStop Blade Complex (NSBC) firmware on the other flash, as follows:
1) Using the OSM Service Connection and the Blade Complex Firmware Update
guided procedure, complete the dialog boxes, altering the T0287 HSS, Primitive
State, and IPF firmware subvolumes to point to the SYSnn of the RVU to which
you are reverting; and update the shadow firmware on each NonStop Blade Element.
For example, if your current coldload subvolume is SYS00 and you intend to
coldload H06.08 from SYS01, you would change the IPF firmware subvolume from
$SYSTEM.SYS00.IPFFIRMW to $SYSTEM.SYS01.IPFFIRMW
NOTE: Update all NonStop Blade Elements in the complex at this time.
2) Using the Switch Blade Element Firmware Images dialog box, select NO.
3) Repeat steps 1 and 2 for the other NonStop Blade Complexes.
c. Halt and then power cycle all processors:
1) Using OSM Low-Level Link, halt all the logical processors in the system.
2) Load (coldload) the system with the RVU to which you are reverting.
Reverting to Previous NonStop Blade Complex Firmware 123