H06.12 Software Installation and Upgrade Guide

.
.
To Point SWAN Concentrators to the New Firmware Object Code File
Use the SCF ALTER ADAPTER, KERNELCODE command:
-> SCF ALTER ADAPTER $ZZWAN.#conc-name,
KERNELCODE swan-kernel-micode-file-name
By default, the SWAN firmware object file (C7953P00) resides in the $SYSTEM.CSSnn subvolume
(nn is the number of the $SYSTEM.SYSnn where the new operating system image resides):
SCF ALTER ADAPTER $ZZWAN.#S01, KERNELCODE $SYSTEM.CSS04.C7953P00
NOTE: The SWAN concentrators (ADAPTER object) must be in the STOPPED state for this
command to work.
The SCF ALTER ADAPTER, KERNELCODE command changes the firmware file location for
all CLIPs associated with a SWAN concentrator.
To Start the SWAN Concentrator and CLIPs
After the SWAN CLIP firmware has been updated, use the SCF START command to start the
updated SWAN concentrator and CLIPs.
SCF START ADAPTER $ZZWAN.#S01, SUB ALL
To Verify That the SWAN CLIPs Are Running the Latest Firmware
Verify that the updated SWAN CLIPs are in fact running at least the firmware version by using
one of the methods described under “To Check Location and Version of New SWAN CLIP
Firmware” (page 151):
Enter the SCF STATUS SERVER $ZZWAN.#conc-name.clip-num, DETAIL command:
$SYSTEM ZWANTOOL 14> scf status server $zzwan.#s01.3, detail
To Start Stopped Lines
Starting the SWAN concentrators should bring all lines into the STARTED state. Check the status
of the lines and, if necessary, start any stopped lines on the started CLIPs for each SWAN
concentrator.
152 Updating SWAN Concentrator CLIP Firmware