H06.15 Software Installation and Upgrade Guide

Table 8 Upgrade Checklist (continued)
Done?ReferenceTask Description
“Receive New Software Into the Archive” (page 83)8. For those with DSM/SCM Planner
Interface, receive this RVU SUT into
DSM/SCM software archive.
“Create a New Software Revision” (page 73)9. For those with NonStop Software
Essentials, create this RVU software
configuration revision.
“Create a New Software Revision” (page 87)10. For those with DSM/SCM Planner
Interface, create this RVU software
configuration revision.
“Build and Apply the New Software Revision (page 76)11. For those with NonStop Software
Essentials, build and apply this RVU
software revision.
“Build and Apply the New Software Revision (page 90)12. For those with DSM/SCM Planner
Interface, build and apply this RVU
software revision.
“Print Operator Instructions From the Target Interface
(ZPHITI)” (page 94)
13. Print DSM/SCM Operator
Instructions.
Chapter 8: “Running ZPHIRNM ”14. Run ZPHIRNM.
“2. Halt the Processors” (page 105)15. Halt processors.
Cluster I/O Protocols (CIP) Configuration and
Management Manual
16. If CLIMs are present, update CLIM
software on all CLIMs using the
procedure “Performing the CLIM
Software Upgrade Using OSM
Low-Level Link.” (If you are migrating
from H06.17 or a later RVU and
performed an online upgrade of the
CLIM to the CLIM software released
with this RVU before starting the host
system upgrade, you can skip this
step.)
“6. Loading the System” (page 105)17. Load system with this new RVU.
“Managing Maintenance Entity (ME) Firmware and ME
FPGA Firmware” (page 24) and the CSSI web page
18. Update ME and ME FPGA
firmware, if necessary.
“Managing NonStop Blade Complex Firmware
(page 27)
19. Update NonStop Blade Complex
(NSBC) firmware.
“Managing ServerNet Adapter Firmware” (page 31)20. Update G4SA Download Code
firmware, if necessary.
“Managing ServerNet Adapter Firmware” (page 31)21. Install ISP1040 firmware, if
necessary.
“Managing ServerNet Adapter Firmware” (page 31)22. Update FCSA firmware, if
necessary.
“Update NonStop TCP/IP Configuration Files” (page 113)23. Recover the TCP/IP files, if
necessary.
“Check Processor Status ” (page 60)24. Check processor status.
“Configure the WAN Manager” (page 116)25. Configure WANMGR, if
necessary.
SWAN Concentrator Installation and Support Guide or
SWAN 2 Concentrator Installation and Support Guide
26. Update SWAN concentrator CLIP
firmware , if necessary.
“Start User and System Applications” (page 111)27. Start system software.
Upgrade Checklist 57