H06.17 Software Installation and Upgrade Guide HP Part Number: 518661-010 Published: August 2012 Edition: H06.
© Copyright 2009, 2010, 2011, 2012 Legal Notice Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents About This Document...................................................................................11 Supported Release Version Updates (RVUs)................................................................................11 Intended Audience..................................................................................................................11 New and Changed Information in This Edition............................................................................
Kernel-Managed Swap File (KMSF)......................................................................................36 IOAM and Migrating Existing Data to an Enterprise Storage System (ESS).................................36 OSS Database Files...........................................................................................................36 Installing OSS Products Not Managed by DSM/SCM.............................................................37 OSS General Alerts and Considerations...........
H06.15..................................................................................................................................55 Compiling C++ Programs to Run on RVUs Earlier Than H06.15................................................55 SQL/MX Versioning Feature Removed..................................................................................55 H06.16..................................................................................................................................
Recovery for Problems Installing This RVU SUT or SPRs...............................................................101 Cancel Pending Build/Apply Requests................................................................................101 8 Running ZPHIRNM ................................................................................102 Alerts..................................................................................................................................
12 Running ZPHIRNM to Reactivate the Previous Software Revision..................129 Alerts..................................................................................................................................129 Drain the Spooler (Optional)..................................................................................................129 Run ZPHIRNM......................................................................................................................129 Using PREVIEW Mode......
SPRNOTES......................................................................................................................166 Install SPRs With DSM/SCM .................................................................................................167 Save the Current Configuration..........................................................................................167 Determine the Current SYSnn.............................................................................................
Copy the ZDSMSCM Client File From the Host.....................................................................188 Install the DSM/SCM Client Software.................................................................................189 E Updating SWAN Concentrator CLIP Firmware............................................194 Glossary..................................................................................................195 Index.......................................................................
Tables 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Tasks and Tools for Backing Out to the Previous SYSnn .........................................................23 Maintenance Entity (ME) Firmware File Names and Locations................................................26 Maintenance Entity (ME) FPGA File Names and Locations.....................................................27 H-Series ServerNet Adapters File Names and Locations........................................................
About This Document This guide describes: • Upgrading the initial H06.17 RVU through the use of site update tape (SUT) refreshes, if necessary. • Falling back to a previous SYSnn. This document might be revised between DVD publications. A more recent version of this document might exist online in the HP Integrity NonStop H-Series collection of the NonStop Technical Library (NTL) at http://www.hp.com/go/nonstop-docs. Supported Release Version Updates (RVUs) This manual supports the H06.17.
• Duplicate information has been removed from “Installation, Migration, and Fallback Considerations” (page 36). • “DSM Tape Catalog Migration” (page 54) has been added to “H06.13” (page 54) in Chapter 3. • “CLuster I/O Module (CLIM)” (page 57) has been added to “H06.16” (page 55) in Chapter 3. • A note to prevent overwriting the original inetd.conf file has been added.
• Upgrading HP NonStop system console workstation applications. To install or upgrade HP and third-party system console client software, such as OSM client-based components, see the NonStop System Console Installer Guide. • Installing and configuring OSM server components. To install and configure OSM server components, and start using client-based components, see the OSM Migration and Configuration Guide. • Installing, configuring, and migrating to HP NonStop SQL/MX.
Related Information NOTE: Many of the documents referenced in this guide are located in the NTL, which has moved to the HP Business Support Center (BSC) at http://www.hp.com/go/nonstop-docs. See Tips for Locating NonStop Documents in the BSC for information about locating NonStop documents. • The NonStop Firmware Matrices provides firmware levels for all RVUs. • The CLuster I/O Module (CLIM) Software Compatibility Reference provides the compatibility information of CLIM DVD SPRs and host RVUs.
1 Overview of Installing This RVU This chapter introduces the basic installation tools and requirements in H-series RVUs, including installing the site update tape (SUT) for a release version update revision (RVUR). For information on installing software product revisions (SPRs), see “Using DSM/SCM and NonStop Software Essentials to Install SPRs” (page 159). SUT on DVD Beginning with the H06.06 RVU, the H-series SUT is also available on DVD.
• Compaq TSM is not supported in H-series RVUs. You must use OSM. For many update tasks, you can still use the Subsystem Control Facility (SCF). • The OSM Low-Level Link features a new System Load Configuration dialog specifically for H-series RVUs. This system load and save configuration feature is much more flexible than previous save configuration options used in G-series RVUs. The mirrored system disk can have an independent adapter and location from the primary system disk.
Updating System Consoles (Optional) HP recommends that you always update to the latest NSC installer DVD. If you have ordered new system consoles for this RVU, the latest client-side software is already installed; if not, obtain the latest NSC installer DVD. See the NonStop System Console Installer Guide for detailed information on installing the system console software. If you have NonStop Software Essentials installed on a different HP SIM CMS, update it there.
• ◦ Fibre Channel disk drives and Environmental Monitoring Units (EMUs), located within FCDMs ◦ SWAN CLIPs ◦ Legacy S-series components supported in H-series RVUs Recent enhancements include system-level actions to: ◦ Perform data sanitization ◦ Configure an NS16000–series system as a member of a BladeCluster ◦ Test incident report delivery paths for HP Insight Remote Support Advanced (which is an alternative to using the OSM Notification Director for remote services) • Support for using HP S
◦ OSM Certificate Tool ◦ NonStop Maintenance LAN DHCP DNS Configuration Wizard (replaces the CLIM Boot Service Configuration Wizard on NonStop System Console Installer DVD, Update 17 and later) For more information, see the NonStop System Console Installer Guide. NOTE: The OSM Notification Director has been removed from the NSC DVD; it will not function on consoles running Windows 2008 Server. Its functionality has been replaced by HP Insight Remote Support Advanced.
DSM/SCM and This RVU • The DSM/SCM H02 PVU (T6031H02) is supported. • A new type of hardware platform and selectable option, TNS/E, has been added to the Planner Interface (PI) screens. See the DSM/SCM User’s Guide for configuration information. • By default, the DSM/SCM H02 PVU is configured to manage OSS files. Check that OSS is configured and started if DSM/SCM is set to manage OSS files. If not, the Apply can fail.
that OSS is installed and configured. However, the OSS root fileset ($ZPNS) must be in the started state; otherwise, the Build/Apply fails. Upgrading the NonStop Software Essentials Client You can now order 64-bit consoles, which require NonStop Software Essentials. (NonStop Software Essentials is pre-installed on the 64 bit consoles. See the NonStop Software Essentials Installation and Quick Start Guide for how to install it.
names of currently running programs. You run the ZPHIRNM program on the target system to: • Rename the files that currently have actual file names to fabricated names. These files become obsolete when the new files are renamed. • Rename the new files, which have fabricated names, to their actual names.
FILES_TO_COPY_TO_NEW_SYSTEM SYSTEM_IMPLICIT_INIT_FILES SYSTEM_IMPLICIT_CORE_FILES SYSTEM_IMPLICIT_FS_FILES SYSTEM_IMPLICIT_MCP_FILES SYSTEM_IMPLICIT_ETC_FILES FORMATTER_TEMPLATE_FILES INITIAL_COMINT_INFILE TANDEM^FILES^TO^COPY; TANDEM^IMPLICIT^INIT^FILES; TANDEM^IMPLICIT^CORE^FILES; TANDEM^IMPLICIT^FS^FILES; TANDEM^IMPLICIT^MCP^FILES; TANDEM^IMPLICIT^ETC^FILES; TANDEM^FORMATTER^TEMPLATE^FILES; $DSMSCM.SYS.
Product Name G-series Product ID T-Numbers HP NonStop Simple Object Access Protocol (SOAP) SX21V3 becomes HSX21 T0535 (not moved to H-series), T0563, T0601, T0603, T1100 (not moving to H-series) NonStop XSLT Translator SX22V2 T0592 (not moved to H-series), T0601 NonStop SOAP Client SX24V1 T0624 NonStop Fast XML Parser SX25V1 T0625 1 NonStop Pathway/iTS with TS/MP (SR76V1) in G-series becomes NonStop Pathway with TS/MP in H-series.
2 Managing Microcode and Firmware NOTE: Trained HP service providers will update the firmware when they install any field-replaceable units (FRUs). Firmware, unless otherwise noted, is considered customer-updateable. You must manage all microcode and firmware within your system properly, ensuring compatible versions are installed. Failure to do so can result in a wide range of system problems, from intermittent faults to partial or complete system outages.
To determine whether your system has processor switches, IOAMs, or VIO enclosures, see the planning guide for the system. • • “Updating ME Firmware” ◦ Updating ME Firmware on a Processor Switch ◦ Updating ME Firmware on an I/O Adapter Module ◦ Updating ME Firmware on a VIO Enclosure “Updating ME FPGA” For information on using OSM Low-Level Link to perform ME firmware updates, see the online help available within the application.
Updating ME Firmware on an I/O Adapter Module (IOAM) There is maintenance entity (ME) firmware on the ServerNet Switch Board object in each I/O Adapter Module. NOTE: In the OSM Low-Level Link, a ServerNet Switch Board is represented as an ME object. To use the OSM Service Connection to update the ME firmware for IOAMs: 1. Locate the ServerNet Switch Board on one Internal ServerNet Fabric. 2. 3. 4. 5.
Use the OSM Service Connection to check and (if necessary) update the ME FPGA for all processor switches, IOAMs, and VIO modules just as you did when updating ME firmware, but choose the ME FPGA Update action instead. For information on using the OSM Low-Level Link to update ME FPGA, see the online help available within the application. Managing NonStop Blade Complex Firmware Different server types have different blade firmware requirements.
Updating Blade Complex Firmware for NS14000 Series Systems and NS16000 Series Systems You can update firmware one NonStop Blade Element at a time or all slices (Blade Elements) at the same time. However, reset and reintegration is performed on one NonStop Blade Element at a time. OSM notifies you to reset and then reintegrate the updated NonStop Blade Element with the running NonStop Blade Elements.
NonStop Blade Complex Firmware Update for Migrations From H06.03 or H06.04 to This RVU CAUTION: Do not power cycle any NonStop Blade Element until the firmware update is complete. If you interrupt or stop the procedure before the firmware update has completed, the NonStop Blade Element firmware will be left in an incomplete and inconsistent state. Also, if there is an interruption during the firmware update, do not reset or power cycle the NonStop Blade Elements.
1) 2) 3) Using the OSM Service Connection and the Blade Complex Firmware Update guided procedure, complete the dialog boxes and update the shadow firmware on each NonStop Blade Element. NOTE: OSM will preselect all the firmware that it detects as down-rev. NOTE: Update all NonStop Blade Elements in the complex at this time. Using the Switch Blade Element Firmware Images dialog box, select NO. Repeat steps 1 and 2 for the other NonStop Blade Complexes.
Managing ServerNet Adapter Firmware This manual covers only the ServerNet adapters supported on H06.14 and later RVUs: • Fibre Channel ServerNet adapter (FCSA) • Gigabit Ethernet 4-port ServerNet adapter (G4SA) • Token Ring ServerNet adapter (TRSA) • 6763 Common Communication ServerNet Adapter (CCSA) To update firmware for ServerNet adapters connected to legacy IOMF2 CRUs, see the latest G-series Software Installation and Upgrade Guide.
• G4SA. The OSM Service Connection displays G4SA firmware attributes and action under the G4SA SAC object. To check or update G4SA firmware, locate and expand the G4SA, then select its subcomponent G4SA SAC object. In the following example, the firmware attributes show that the current firmware Version is the same as the available Default File Version; no update is necessary.
Table 4 H-Series ServerNet Adapters File Names and Locations (continued) Description Component File Name Default Location Tool Related Information G4SA firmware G4SA C0612R00 SYSnn subvolume OSM Service Connection or SCF Gigabit Ethernet 4–Port Adapter Installation and Support Guide Distributes SCSI I/O Interface Boot Flash Board Firmware download code for OSM Update function. The ISPFIRMW file is now contained in this product.
For information on required software, installation, migration, and fallback procedures, see the ServerNet Cluster 6780 Planning and Installation Guide. Table 5 (page 35) lists the file name and locations for the updateable firmware information for the cluster switch. Check with Scout for the latest SPRs. See the NonStop Firmware Matrices document at: www.hp.com/go/nonstop-docs for product levels.
3 Installation, Migration, and Fallback Considerations See the Readme file and the appropriate softdocs for the latest information on any migration or configuration steps. Considerations in this chapter are categorized according to the RVU at which they were introduced. H06.03 Kernel-Managed Swap File (KMSF) Servers running H-series RVUs require more swap space than do NonStop S-series servers. The default is 512 megabytes for each processor.
Installing OSS Products Not Managed by DSM/SCM Use COPYOSS or PINSTALL or both to install products that are not managed by DSM/SCM. • If any OSS files are managed by DSM/SCM, use PINSTALL on the remaining pax archives. See the OSS Management and Operations Guide for a description of PINSTALL use or the pinstall(1) reference page in the OSS Shell and Utilities Reference Manual. • If no OSS files are managed by DSM/SCM, use COPYOSS for all of the OSS pax archives in the ZOSSUTL subvolume.
PSTATE (T0705H01) and WHOHAS (T0706H01) PSTATE and WHOHAS are two tools that are owned and supported by the Global NonStop Solution Center (GNSC). As of H06.03 and G06.26, these two tools are delivered to customers on the SUT. • PSTATE provides a snapshot of the status of a running process. It provides everything that TACL STATUS, DETAIL does plus information about all files open by the process and what I/Os are outstanding. • WHOHAS provides a list of processes that have open files.
C/C++ Default Floating-Point Type Change Beginning in the H-series RVUs, the default floating-point format used by the C/C++ compiler is changed. In G-series, the default is Tandem floating-point format; on H-Series, the default IEEE format. The two formats are incompatible; an application must consist of either all Tandem format modules or all IEEE format modules. Certain HP-supplied libraries use the default IEEE format. If user programs also use the default format, there is no problem.
in a three-zone configuration, you must install the H06.05 or later H-series RVU or the T0502H01^AAP or later SPR. HP recommends upgrading your servers to the H06.05 or later H-series RVU if the servers will be connected to a long-distance ServerNet Cluster. If the long-distance cluster also contains NonStop S-series servers, HP recommends upgrading those servers to the G06.28 or later G-series RVU. H-series RVUs starting with H06.05 contain T9050H02^AQD or later, and G-series RVUs starting with G06.
Since the new T-number T0744 is replacing the previous T27nn T-numbers, click Continue without selecting any of the T27nn T-numbers. DSM/SCM will remove those T-numbers from your configuration and install T0744. TNS/R Compilers and Tools on H-Series Systems Use One Platform for G-Series and H-Series Development Beginning with H06.05, the G-series TNS/R compilers and development tools are supported in H-series RVUs.
For more information about support for G-series tools on H-series systems, see the H-Series Application Migration Guide or the individual manuals for the tools. TNS/R SRLs Consolidated Into a Single T-Number The TNS/R cross compiler SRLs are consolidated into a single T-number, T8888 (named “TNS/R cross compilers SRLs”). This T-number contains all of the runtime libraries and object files that make up the cross compiler environment.
For reporting problems with any of these SRLs in H-series systems, you should specify the new T-number T8888. The fix will be available via T8888. If you do report a problem against the old T-number (for example, T8432 for ZCRTLSRL), the fix will still be available via T8888. H06.06 OSS Large Files Starting with the H06.06 RVU, OSS files larger than the previous 2 GB limit (large files) are supported. The OSS file system and utilities are able to handle file sizes up to 1 terabyte.
DSAP/DCOM Migration The DSAPDDL file is changed in the product revision of DSAP/DCOM delivered in the H06.06 and later RVUs (T9543H01^ABH), resulting in changes to the work file layout. You must use the DSAPDDL file distributed with T9543H01^ABH when running ENFORM queries on the work file created using this SPR. The DSAPDDL file for T9543H01^ABH contains these changes to the directory-record structure: • The field named fifth is changed from type binary unsigned to type binary 32 unsigned.
Guardian applications that use file attributes such as file format and maximum size are likely to be affected. These programs might fail when unexpected values are returned (such as Format 2 if only Format 1 is expected). If a Format 2 file does cause a program to fail, the programmer can do one of the following: • Change the program to accept Format 2 files.
Safeguard Password Encryption The H03 and later versions of Safeguard and Standard Security improve the cryptology of the user passwords in the NonStop server environments. If PASSWORD-ALGORITHM is DES or PASSWORD-ENCRYPT is OFF, the password (DES-encrypted or in clear text, respectively) is written to both the existing L/USERID and the new L/USERAX files. This approach allows for direct fallback to prior versions of Safeguard and Standard Security.
1. 2. 3. 4. Before starting Safeguard, the system administrator must log on with the old super ID password. The old password is the one used before the algorithm was changed to HMAC256. Start Safeguard. The system administrator must set a grace period for users to change their expired passwords.
These compiler versions provide the required command line options for running the Code Profiling utilities. Starting in the H06.09 RVU, the Profile Merge Utility (T0747) and Code Cover Utility (T0746) are included on the SUT and on the cross-compiler CD. Previously, the Profile Merge Utility was delivered only on the SUT. Safeguard Support for OSS Access Control List The H03 and later versions of Safeguard and Standard Security are enhanced to support the OSS Access Control List (ACL) feature.
Safeguard Longer Password Length Starting with the H04 version of Safeguard, the maximum allowed Safeguard password length is increased from 8 bytes to 64 bytes. Migration Users migrating to a version of Safeguard and Standard Security that supports longer passwords should be aware that two new attributes are introduced: PASSWORD-COMPATIBILITY-MODE and PASSWORD-MAXIMUM-LENGTH. The default setting for PASSWORD-COMPATIBILITY-MODE is ON, meaning that new passwords are limited to 8 bytes.
Compiler Default Change for Object Code Generation Prior to the H06.08 RVU, the native C/C++, COBOL, and pTAL compilers generated preemptable object code by default. Beginning in H06.08, the compilers generate non-preemptable object code by default. Non-preemptable object code is more efficient than preemptable object code and results in faster compilation and execution. Preemptable object code is required only when building DLLs that provide preemptable symbols. The H06.
Migration Considerations If a Maintenance Switch or UPS has been configured in a prior version of OSM, the OSM Access Community Names will not be available. OSM will attempt to access it with the default values of “public” for read access and “private” for Write access. If these are not the values with which the device has been configured, the device will be displayed as “Down.” To recover, do one of the following: • Stop monitoring, and restart monitoring with the correct values.
Fallback Embedded spaces in passwords are not supported in pre-H06.09 RVUs. Any user with a password that contains embedded spaces will be unable to login after fallback. Fallback considerations are: • Pre-H06.08 RVUs do not support the Safeguard longer password feature. Therefore, when falling back to a pre-H06.08 RVU, users must first follow the steps described under “Fallback in a Safeguard Environment” (page 46). • When falling back to H06.
Pathway/iTS 1.1 Pathway iTS/1.1, introduced in the H06.10 RVU, supports the following SCOBOL statements: • DIALOG-BEGIN • DIALOG-SEND • DIALOG-ABORT • DIALOG-END These statements enable users to send more than 32000 bytes of data to the same Pathway server using a context-sensitive communication model. These new features are provided by the PathTCP4 (T0700) component of Pathway/iTS. Migration Pathway/iTS 1.1 includes both PathTCP3 and PathTCP4. PathTCP3 is unchanged.
H06.12 DSM/SCM and OSBUILD If an H06.12 or later host system is used to perform DSM/SCM builds for a target system that is running a release prior to H06.12, you must install the appropriate T0431 (OSBUILD) SPR for that target system before performing the build. If this is not done, then the DSM/SCM Sysgen (OSBUILD) will fail. The build will complete successfully if it is being done for an H06.12 or later system. See “DSM/SCM and This RVU” (page 20) for a list of the required SPRs. H06.
Migrating From TS/MP 2.0 After the system image is built using TS/MP 2.3, TS/MP 2.0 users need to remove #ROUT from Persistent Manager ($ZZKRN) and configure #ZACS before starting TS/MP 2.3 Migrating From TS/MP 2.1 If you ordered and received TS/MP 2.1 on a prior H-series RVU, you will automatically receive TS/MP 2.3 instead of TS/MP 2.1 when you receive an H06.14 or later SUT. H06.15 Compiling C++ Programs to Run on RVUs Earlier Than H06.15 Objects compiled by the H06.
When migrating to AF_UNIX Release 2: • If you start $ZPLS in a startup script using the SCF START SERVER command, and failure to start $ZPLS causes the script to be aborted and steps following the failing one to be omitted, modify the script to remove the command to start $ZPLS. NOTE: • In AF_UNIX Release 2, any changes to the #ZPLS attributes will have no effect. If you use the STARTOSS utility to start OSS processes, modify the target-volume.ZOSSINS.
CLuster I/O Module (CLIM) The CLuster I/O Module (CLIM) is introduced in the H06.16 RVU. CLIM is a rack-mounted HP ProLiant class server that provides connectivity between the NonStop host system and either the network or the storage devices. For CLIM upgrade procedures, see the Cluster I/O Protocols (CIP) Configuration and Management Manual. NOTE: Because H06.16 is the earliest H-series RVU to support CLIMs, you cannot fallback CLIMs on an H06.16 RVU system to an earlier H-series RVU.
DSM/SCM Upgrade Issues/Interoperability SPR Requirements If you are migrating from an H06.16 or earlier RVU to an H06.17 or later RVU, be aware that all the DSM/SCM target systems should be upgraded before the DSM/SCM host is upgraded. The snapshot file created by T6031 H02 ACL has changed and cannot be read by earlier versions of DSM/SCM. See Support Note S09036 for more information.
4 Upgrade Checklist Use the checklist in “Upgrade Checklist” (page 60) to track your progress as you perform the tasks required to upgrade to this RVU and the checklists Table 6 and Table 7 (page 60) to record the information needed when performing these tasks.Table 9 (page 62) lists SPRs that should be installed before upgrading to this RVU. CAUTION: (page 60).
Table 6 Required Information Checklist, Before You Start (continued) Type of Information Value ServerNet Cluster firmware • Cluster Switch • Cluster Switch (logic board; router-2) DSM/SCM product version (server and client) Processor type Record the information in Table 7 while you perform the upgrade.
Table 8 Upgrade Checklist (continued) Task Description Reference 8. For those with DSM/SCM Planner Interface, receive this RVU SUT into DSM/SCM software archive. “Receive New Software Into the Archive” (page 87) 9. For those with NonStop Software Essentials, create this RVU software configuration revision. “Create a New Software Revision” (page 77) Done? 10. For those with DSM/SCM Planner “Create a New Software Revision” (page 91) Interface, create this RVU software configuration revision. 11.
Table 8 Upgrade Checklist (continued) Task Description Reference Done? 27. Update SWAN concentrator CLIP SWAN Concentrator Installation and Support Guide or firmware , if necessary. SWAN 2 Concentrator Installation and Support Guide 28. Start system software. “Start User and System Applications” (page 116) 29. Configure OSS, if necessary. “Configure OSS” (page 120) 30. Configure SMF, if necessary. “Configure SMF (Optional)” (page 121) 31. Configure RDF, if necessary.
5 Preparing to Upgrade the Server Software (Pre-installation Tasks) This chapter describes tasks that are needed before updating the system console and receiving the SUT. Back Up Important Files Before you upgrade, create tape back-ups of critical host applications and files. Back Up NonStop SQL/MP HP recommends that you always have a current backup copy of the $SYSTEM.SYSTEM.ZZSQLCI2 file in case you need to initialize SQL later if you have problems with your new RVU during or after installation. 1.
If you are upgrading from H06.16, create a subvolume to store the backups, then rename each backup file after you create it. The default file name for the backup is backupgz. Rename these as you create them. For example: 1. CLIMBKUP N100251 $DATA1.BCKH0616 2. FUP RENAME $DATA1.BCKH0616.BACKUPGZ, $DATA1.BCKH0616.N100251 3. CLIMBKUP N100282 $DATA1.BCKH0616 4. FUP RENAME $DATA1.BCKH0616.BACKUPGZ, $DATA1.BCKH0616.N100282 For upgrades from H06.
Verify System Processes Check Processor Status 1. Log on to the OSM Low-Level Link. The OSM Low-Level Link Application appears. 2. Select Processor Status. The Processor Status dialog box appears. The Processor Status for all processors should be Executing NonStop OS. Check System Components 1. Log on to the OSM Service Connection. See the OSM Migration and Configuration Guide if you have any problems accessing OSM. After the browser session begins, you can close the original IE window.
The System Status window indicates the overall health of a system by the color of the system icon. From the Summary menu, select System Status. Yellow indicates a possible system problem. For example: 2. Double-click to expand the object further to identify components that require attention (yellow or a yellow arrow) or immediate service (red). CAUTION: If a red triangle appears over an object, or if any component is highlighted in red, contact your service provider. 3. 4.
Verify the State of the Internal ServerNet Fabric To verify that the paths and connections within the ServerNet system area network (ServerNet SAN) are properly functional: 1. Log on to the OSM Service Connection. 2. In the tree pane, double-click the Fabric Group. 3. For each Internal ServerNet Fabric, double-click the fabric. 4. Select each Processor Switch Power Supply. 5. In the Attributes tab, if the Service State attribute is visible, verify that it has a value of OK.
Verify Critical System Processes 1. From a TACL prompt, log on to the system using the super ID (255,255). Enter the LISTDEV command: > SCF LISTDEV $ADBIT RESULTS 18> scf SCF - T9082H01 - (01MAY05) (15MAR05) - 05/09/2005 16:13:56 System \ATLAS (C) 1986 Tandem (C) 2003 Hewlett Packard Development Company, L.P. (Invoking \ATLAS.$SYSTEM.STARTUP.
LDev Primary 151 *STARTED Backup Mirror MirrorBackup STARTED *STARTED STORAGE - Status DISK \ATLAS.$ADBIT LDev Primary Backup Mirror 150 *STARTED STARTED MirrorBackup *STARTED STORAGE - Status DISK \ATLAS.
Name ZCSAM PROV1 Status STARTED STARTED TPStatus Started Invalid Trace OFF (0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15) Check the Status of the Spooler Collector Check that the spooler collector is active and not 100 percent full. At a TACL prompt, start SPOOLCOM and issue a COLLECT, STATUS command. For example: 1> spoolcom $spls; collect, status COLLECT $S STATE ACTIVE FLAGS 3 , CPU 1 PRI 154 UNIT 4 DATA FILE $OPS0.SPL.
Peak CPU Pages ever reserved 15239 Threshold 86959 CPU pages * Default swapfile extents may not be fully allocated. Status of $SYSTEM.ZSYSSWAP.SWAP02 CPU 2 CPU Pages: Total 102305* Reserved 6361 Available 95944 Peak CPU Pages ever reserved 7280 Threshold 86959 CPU pages * Default swapfile extents may not be fully allocated. Status of $SYSTEM.ZSYSSWAP.
Table 12 lists the specific SPRs that must be installed on systems running G-Series RVUs for compatibility and interoperability through a ServerNet Cluster with systems running H-Series RVUs. Table 12 Interoperability SPRs for G-Series RVU Systems Connected through ServerNet to H-Series RVU Systems Minimum SPR Product Name Description Introduced in this RVU T0294G08^AAP SNETMON Required for ServerNet clustering* G06.26 T0502G08^AAN SANMAN Required for ServerNet clustering* G06.
Table 14 H-Series and J-Series RVUs Needing SPRs for Nodes to Interoperate with SQL/MX 2.3.4 (H06.20 and Later RVUs) H-Series J-Series H06.10.00 H06.10.01 H06.11.00 H06.11.01 H06.11.02 H06.11.03 H06.12 H06.13 H06.14 H06.15.00 H06.15.01 H06.15.02 H06.16.00 H06.16.01 H06.17.00 H06.17.01 H06.17.02 H06.18.00 H06.18.01 H06.19 H06.20 J06.03 J06.04.00 J06.04.01 J06.04.02 J06.05.00 J06.05.01 J06.06.00 J06.06.01 J06.06.02 J06.07.00 J06.07.01 J06.08 J06.
6 Installing a SUT for This RVU Using NonStop Software Essentials NOTE: If you do not have NonStop Software Essentials installed, see the NonStop Software Essentials Installation and Quick Start Guide. Installing a new RVU or a SUT involves these DSM/SCM tasks: 1. “Receive New Software Into the Archive” (page 87) 2. “Create a New Software Revision” (page 77) 3.
> TMFCOM START TMF > VOLUME $dsmscm_vol.ZDSMSCM > RUN STARTSCM startscm NOTICE: * * * * If the hometerm chosen during INITENV, $zhome, is not currently in a paused state, STARTSCM and DSM/SCM server processes may hang indefinitely.
8. Select Tape drive. 9. From the list, select the tape drive that contains the SUT. 10. Click the Scheduling tab. Make the appropriate selections. 11. Click Submit. The request status page appears and is updated automatically. 12. While waiting for the request to finish, check: 76 • The status of the request in the Status window. For example: • EMS event messages to see if a cartridge on a non-autoloading drive of the SUT needs to be mounted.
13. Expand the SUTs node in the navigation tree and monitor the request status page. When the request completes, the new SUT will appear at the top of the list of SUTs. 14. Keep the NonStop Software Essentials page open for the next task. Create a New Software Revision When you create a new software revision, NonStop Software Essentials selects the products in the SUT that are licensed for your site and replaces any previous versions of the products.
b. c. Click the Output tab to view the default output values. Enter the appropriate values in the data fields. NOTE: On H-series systems, the alternate name for the $SYSTEM drive now defaults to $FC1 for fibre channel drives or $SCSI for SCSI drives. If this default has been changed, then the target volume specified in NonStop Software Essentials for new subvolumes must reflect this change. 4. 5. Click OK to return to the Configuration Revisions page.
If there are any discrepancies between the set of products included in the previous configuration and the set in your new configuration, the popup shown below is displayed. (These products are removed from the system by DSM/SCM during the Build/Apply of the new configuration.) The dialog box lists products installed on the previous revision that are not available on the new SUT. To retain these products from the current revision into the new revision: • Select the products and click Continue.
7. Keep the NonStop Software Essentials page open for the next task. Build and Apply the New Software Revision The Build process creates an activation package containing all the products listed in the new software revision. To avoid disrupting other system activities, schedule the Build to run at night and the Apply to run immediately after the Build. To build and apply the new software revision: 1.
3. 4. Under Perform steps, select Build, apply & process snapshot. In the Activation SYSnn: box, enter a unique number to create a new SYSnn subvolume. The value nn must be a two-digit octal number in the range %00...%77. You can issue a FILEINFO command at a TACL prompt to view the SYSnn subvolumes that are currently on your system. > fileinfo $system.*.osimage 5. 6. 7. Make a note of the new SYSnn.
8. (Optional) Confirm that the spooler is active and not 100 percent full before executing the Build/Apply request. At a TACL prompt, start SPOOLCOM and issue a COLLECT, STATUS command. For example: 12> spoolcom $spls; collect, status COLLECT $S 9. STATE ACTIVE FLAGS 3 , CPU 1 PRI 154 UNIT 4 DATA FILE %FULL $OPS0.SPL.DATA 4 In the Build/Apply Request page, click Submit Build/Apply.
• The last message in the EMS Events window shows that the input snapshot finished successfully. • The Requests window shows that the request is finished. (Select Requests> Show Requests). 11. Exit NonStop Software Essentials. Print Operator Instructions From the Target Interface (ZPHITI) Print the operator instructions that you edited. 1.
Selection number: 0 ============================================================================== Choose an action by entering the selection number of an item from the list below.
F1-Select F15-Help F16-Return SF16-Exit Ready 5. 6. Enter 3 (Review operator instructions for the last apply completed) in the Selection number field, and press F1 to display the operator instructions. Enter a printer location in the Print operator instructions field, and press F9 to print the operator instructions. An example instruction screen might look like this: Activation Instructions for \BITDRP BITDRP These are general instructions that were determined from configuration attributes.
The cancel request action takes a few minutes to finish. NOTE: If you cannot cancel the Build request through NonStop Software Essentials, use the DSM/SCM Target Interface (ZPHITI) to cancel the request. See the online help for more information.
7 Installing a SUT for This RVU Using the Planner Interface Installing a new RVU or a SUT involves these DSM/SCM tasks: 1. “Receive New Software Into the Archive” (page 74) 2. “Create a New Software Revision” (page 91) 3. “Build and Apply the New Software Revision” (page 94) Alerts for Installing a SUT Do not use this procedure to upgrade more than one system at a time or to install SPRs. For SPRs, see “Using DSM/SCM and Planner Interface to Install SPRs” (page 166) to install SPRs.
startscm NOTICE: * * * * If the hometerm chosen during INITENV, $zhome, is not currently in a paused state, STARTSCM and DSM/SCM server processes may hang indefinitely.
6. 7. Under Software name, select Provided by planner and enter a name for the RVU. In the Options group box, click Input source. The Request Source Options dialog box appears. 8. 9. Select Tape drive. From the list, select the tape drive that contains the SUT, and click OK. The Request Source Options dialog box closes. 10. In the Options group box of the Receive Software Request dialog box, click Scheduling. The Request Scheduling Options dialog box appears.
• 90 EMS event messages to see if a cartridge on a nonautoloading drive of the SUT needs to be mounted. EMS messages are displayed in these windows: ◦ The EMS Event Stream window ◦ The EMS Events window displayed by DSM/SCM when you click Show EMS events from the Status window ◦ You can also check the Requests window to ensure that the request is finished. (Select Requests>Requests list.
13. When the request is finished, close the Status and Requests windows. 14. Update the Software in Archive dialog box to show the newly received SUT. Select Window>Refresh. The new SUT appears in the window. 15. Keep the Planner Interface open for the next task. Create a New Software Revision When you create a new software revision, DSM/SCM selects the products in the SUT that are licensed for your site and replaces any previous versions of the products.
b. c. Click Output to view the default output values. Enter the appropriate values in the data fields. NOTE: On H-series systems, the alternate name for the $SYSTEM drive now defaults to $FC1 for fibre channel drives or $SCSI for SCSI drives. If this default has been changed, then the target volume specified in the Planner Interface for new subvolumes must reflect this change. d. 3. 4. 5. Click OK. DSM/SCM returns you to the Target Information dialog box.
6. Click Continue when the Confirmation message appears: Note that if there are any discrepancies between the set of products included in the previous configuration and the set in your new configuration, a warning message appears listing any products missing in the current configuration that were present in the previous configuration. (These products are removed from the system by DSM/SCM during the Build/Apply of the new configuration.
7. Keep the Planner Interface open for the next task. Build and Apply the New Software Revision The Build process creates an activation package containing all the products listed in the new software revision. To avoid disrupting other system activity, schedule the Build to run at night and the Apply to run immediately after the Build. See the DSM/SCM User’s Guide for information about scheduling the Build/Apply to run at different times. To build and apply the new software revision: 1.
3. 4. Under Perform steps, select Build, apply & process snapshot. In the Activation SYSnn: box, enter a unique number to create a new SYSnn subvolume. The value nn must be a two-digit octal number in the range %00...%77. You can issue a FILEINFO command at a TACL prompt to view the SYSnn subvolumes that are currently on your system. > fileinfo $system.*.osimage 5. 6. 7. Make a note of the new SYSnn.
9. (Optional) Confirm that the spooler is active and not 100 percent full before executing the Build/Apply request. At a TACL prompt, start SPOOLCOM and issue a COLLECT, STATUS command. For example: 12> spoolcom $spls; collect, status COLLECT $S STATE ACTIVE FLAGS 3 , CPU 1 10. In the Build/Apply Request dialog box, click OK. 96 Installing a SUT for This RVU Using the Planner Interface PRI 154 UNIT 4 DATA FILE %FULL $OPS0.SPL.
DSM/SCM runs the Build and Apply steps and displays a Status window, which is automatically updated at regular intervals. For example: 11. Check EMS messages for more detailed information about your Build/Apply: a. In the Events window, click Refresh to see newer messages. b. When finished viewing, click Close. NOTE: If you encounter any problems, see the DSM/SCM User’s Guide or online help.
• The last message in the EMS Events window shows that the input snapshot finished successfully. • The Requests window shows that the request is finished. (Select Requests> Requests list). 12. Close the EMS Events, Status, and Request windows. 13. Exit the DSM/SCM Planner Interface. Print Operator Instructions From the Target Interface (ZPHITI) Print the operator instructions that you edited. 1.
All Rights Reserved ============================================================================== F1-Logon F8-Clear entry F15-Help SF16-Exit Ready 2. Enter your user ID or alias (if necessary) and password and press F1 to log on to the Target Interface.
DSM Software Configuration Manager Target Menu - Select Action ============================================================================== \WARRIOR Prior snapshot 2003-11-20:12:18:44 DEFAULT Last S/W applied on SYS 00 on 2002-11-22:12:17 Selection number: ============================================================================== Choose an action by entering the selection number of an item from the list below.
You will run merge_whatis after using ZPHIRNM. If you have OSS configured to run the OSS merge_whatis utility automatically, you can ignore running merge_whatis. Recovery for Problems Installing This RVU SUT or SPRs If you receive an error indication in the Requests, Status, or EMS Events windows, you might have to reinitiate the Build/Apply. See the DSM/SCM Messages Manual to determine the nature and severity of the problem.
8 Running ZPHIRNM During the Build/Apply phase, DSM/SCM places product files in their subvolumes with temporary (fabricated) file names so that new file names do not conflict with the file names of currently running programs. This chapter describes how to run the ZPHIRNM program on the target system to: • Rename the files that currently have actual file names with fabricated names. These files become obsolete when the new files are renamed.
• DNSHOSTS • DNSLOCAL • DNSREV • DNREVBAK • HOSTS • NETWORKS • PORTCONF • PROTOCOL • RESCONF • SERVICES • SMTPCONF The file names of NonStop TCP/IPv6 that reside on the SUT are: • ztcpip.smplhost • ztcpip.smplprot • ztcpip.smplnetw • ztcpip.smplport • ztcpip.smplresc • ztcpip.smplserv Stop Applications Before running ZPHIRNM: 1. Stop DSM/SCM if it is still running. For example: > VOLUME $dsmscm_vol.
1. 2. Use the SPOOLCOM;COLLECT $collector-process, LISTOPENS command to identify processes that currently have jobs open. Use the SPOOLCOM;JOB (STATE PRINT) command to determine which jobs are currently printing. Take the appropriate action to ensure that these jobs either terminate when finished or are stopped. After receiving the SPOOLER DRAIN command, the supervisor stops accepting jobs for collection or printing (new opens are rejected with a file-system error 66—device downed).
Files Processed: Files Files Files Files Files Files Files Files Files Files processed in new configuration ........................... processed in new configuration only ...................... processed in old configuration only ...................... processed that are shared by new and old configuration ... processed & unchanged between new and old configuration .. processed in obsolete TSVs ............................... renamed from real name to fabricated name ................
Do you want to use a log file with this session? (Y/N): y You may use any file for logging. If you request to use a disk file that doesn't exist, it will be created as an edit file. Please enter a filename: elist00 Log file is open, Zphirnm will now begin processing. ZPHIRNM begins processing and provides status of its progress. 4. If necessary, you can compare the creation dates of the whatis file to the whatis_old file to see if changes occurred: a. Run the more command against the whatis file: more b.
9 Loading This RVU This chapter describes how to perform a system load of this RVU into the memory of each processor in a NonStop system. NOTE: Guide. For detailed information on performing a system load, see in the NonStop Operations By default, one $SYSTEM is already configured. You can select $SYSTEM, FCDM-Load, CLIM-Attached-Load for systems that support this type of load), or an alternate system volume: The $SYSTEM disks must contain the current RVU operating system files for the NonStop system.
Table 16 System Load Paths in Order of Use for CLIM-Attached-Load Load Path Description Data Travels From To Processor Over ServerNet Fabric 1 Primary $SYSTEM-P 0 X 2 Primary $SYSTEM-P 0 Y 3 Backup $SYSTEM-B 0 Y 4 Backup $SYSTEM-B 0 X 5 Mirror $SYSTEM-M 0 X 6 Mirror $SYSTEM-M 0 Y 7 Mirror backup $SYSTEM-MB 0 Y 8 Mirror backup $SYSTEM-MB 0 X 9 Primary $SYSTEM-P 1 Y 10 Primary $SYSTEM-P 1 X 11 Backup $SYSTEM-B 1 X 12 Backup $SYSTEM-B 1 Y 13 Mir
displayed in the Attributes tab under the System object in the OSM Service Connection and are also displayed in the OSM Low-Level Link System Load dialog box in the Configuration shortcut menu. Alerts Before performing a system load: • Before halting the processors, stop applications that are still running, including TMF.
B. When Upgrading From the H06.03 or H06.04 RVU If you are upgrading from the H06.03 or H06.04 RVU, then before halting the processors, update the shadow firmware on each NonStop Blade Element, as described in step 6a under “NonStop Blade Complex Firmware Update for Migrations From H06.03 or H06.04 to This RVU” (page 30). C. When Upgrading From the H06.16 RVU CLIMs configured with the CLIM software released with H06.16 are not compatible with H06.17 and later RVUs.
For details on load paths, see the hardware installation manual for your NonStop system. Steps for Loading the System A normal system load consists of loading the operating system from disk into the memory of processor 0 or processor 1 (this assumes the default location is the $SYSTEM volume): 1. In the OSM Low-Level Link, select Start System. The System Load dialog box appears. 2. a. From the Configuration drop-down menu under System Load Configuration, select a system load volume.
This example shows the same dialog box for a CLIM-attached load: 112 Loading This RVU
One window opens with one CNSL and one CLCI session in it. NOTE: If you are using OSM Low-Level Link version T0633AAT or later, all four windows are contained within a single MR-Win6530 session window (as opposed to the four separate OutsideView sessions launched by earlier versions of the Low-Level Link.) Also, MR-Win6530 hides the inactive Startup TACL and Event Stream windows, displaying only the active ones.
6. Monitor the system startup process. Messages indicating the progress and completion of the system load, as well as the reload of processors indicated in the CIIN file, appear in these display locations on the system console. When the system load is complete (the operating system is loaded successfully into the memory of processor 0 or processor 1), the Detailed box on the System Load dialog box displays: SYSTEM STARTUP COMPLETE, NSK RUNNING ON PROCESSOR n 7.
2. 3. Close the Processor Status dialog box. Verify that the NonStop operating system is working properly: a. Check the startup TACL window to verify that the startup scripts completed successfully. b. Check the startup event stream window and the startup TACL window for error messages. 4. Close the System Startup dialog box. For more information on system loads, the NonStop Operations Guide. 7.
10 Resuming Normal Operations Revive the Down Half of the Mirrored Disk If you shut down half of $SYSTEM and other mirrored disks before applying the new RVU, revive the disks now. For instructions on how to bring up the downed half of a mirrored disk, see the Guardian User's Guide. Start User and System Applications You can now start your application software. Follow your site’s procedures for executing the system configuration and startup (command) files to accomplish this.
Cold Start the Pathway Configuration 1. 2. Verify your current configuration against the cold start configuration in PATHHOST (or PATHTARG) to check that the current configuration reflects all changes you have made. Run the PATHCOLD macro from the ZDSMSCM subvolume to cold start the Pathway configuration. Start DSM/SCM 1. From the ZDSMSCM subvolume, start DSM/SCM: > RUN STARTSCM Because the $ZHOME reliable home-term process is not an interactive process and is always paused, no action is necessary. 2.
cat3 cat6 whatis /usr/share/man: After you run merge_whatis, the directory contains a file named whatis, containing the database. If you have previously installed OSS, a file named whatis_old is present, containing the previous version of the database. Configure Specific Products (Post-System Load) This section contains information about the configuration of various products such as OSS and SMF. See product-specific documentation for more information on installation and configuration.
>FUP >FUP >FUP >FUP DUP DUP DUP DUP $SYSTEM.ZTCPIP.SMPLNETW, $SYSTEM.ZTCPIP.SMPLPORT, $SYSTEM.ZTCPIP.SMPLRESC, $SYSTEM.ZTCPIP.SMPLSERV, $SYSTEM.ZTCPIP.NETWORKS $SYSTEM.ZTCPIP.PORTCONF $SYSTEM.ZTCPIP.RESCONF $SYSTEM.ZTCPIP.SERVICES Step 2: Check the PROTOCOL File (Optional) CAUTION: For both CIP and NonStop TCP/IPv6 (even if running in IPv4 mode), you must make sure that the PROTOCOL file contains ipv6 and icmpv6 entries.
Applications use the SERVICES file to retrieve the service port numbers and service names. If you copied files as documented in Step 1, check that the last lines of the SERVICES file have an entry similar to: phiwsock 1089/tcp #DSM/SCM Planner Interface For DSM/SCM, the port number is user-definable. The setup default is 1089. In the ZDSMSCM subvolume, check the INITSTAT file for the recently configured TCP/IP port number. INITSTAT is created by DSM/SCM when INITENV is run.
Using OSS EasySetup (T0585) The OSS EasySetup product (T0585) is available for automated setup, as described in the Open System Services Installation Guide. OSS EasySetup is a series of TACL scripts that assist a site when configuring and installing a minimal OSS subsystem for the first time or when starting, stopping, or removing an OSS subsystem.
11 Backing Out the DSM/SCM Revision This chapter describes: • Products that might have fallback implications. Before falling back or backing out the revision, review the appropriate product softdocs. • Using DSM/SCM to back out the revision. NOTE: • You cannot revert a NonStop NS16200 system to the H06.11.03 RVU or to an RVU prior to H06.11.01. • You cannot revert a NonStop NS1200 system to an RVU prior to H06.12. • You cannot revert a NonStop NS14200 system to an RVU prior to H06.13.
Longer Passwords Starting with the version of Safeguard released with the H06.08 RVU, the maximum allowed password length is increased to 64 characters. This change has fallback implications when falling back to pre-H06.08 RVU, as users passwords longer than 8 characters will be unable to logon. See “Safeguard Longer Password Length” (page 49). Before Backing Out the Revision 1. Confirm that the spooler is active and not 100 percent full. a.
DSM Software Configuration Manager Main Menu ============================================================================== \ELI Prior snapshot 2002-04-14:18:03:03 Selection number: 0 ============================================================================== Choose an action by entering the selection number of an item from the list below.
1 Perform/Review apply request 2 Perform backout to S/W Applied on SYS 03 on 2005-04-14:15:41 3 Review operator instructions for the last apply completed. ============================================================================== F1-Select F15-Help F16-Return SF16-Exit Ready 3. In the Selection number field, enter 2 (Perform backout to S/W), and press F1.
F15-Help F16-Return SF16-Exit DSM Software Configuration Manager Backout - Processing Backout ============================================================================== \ELI Prior snapshot 2002-04-14:18:03:03 DEFAULT Last S/W applied on SYS00 on 2002-04-14:18:01 Backout 2000-04-18:11:00:39 ============================================================================== Request is being processed. Status information will appear below indicating progress.
Monitor the Backout Process Using NonStop Software Essentials 1. 2. Log on to NonStop Software Essentials. Select Requests> Show Requests. The Requests status page appears, showing the type and status of various DSM/SCM requests. 3. From the Request list page, click your backout request name. The Request Status page displays detailed information about your backout request. This example indicates that the backout request finished successfully: Monitor the Backout Process Using the Planner Interface 1. 2.
Backing Out the DSM/SCM Revision
12 Running ZPHIRNM to Reactivate the Previous Software Revision Alerts Before running ZPHIRNM: • Applications that use files that are being replaced should not be running. To avoid any possibility of conflict, stop all applications, except for the TMF subsystem, before running ZPHIRNM. • You must have rename (purge) access to all files being renamed. You can ensure this access by running ZPHIRNM as the super ID (255,255).
Run ZPHIRNM 1. At a TACL prompt, enter from the DSM/SCM subvolume: > RUN ZPHIRNM $vol.SYSnn where: • $vol specifies the default current system load volume, usually $SYSTEM. • SYSnn specifies the SYSnn subvolume named previously in the backout request. For example: > RUN ZPHIRNM $system.SYS00 2. 3. 4. When asked if you want to use a log file with the session, type Y and press Enter. When prompted, type a file name for the log file, and press Enter.
13 Falling Back on the CLIMs, Loading the Previous RVU, and Resuming Normal Operations This chapter describes how to perform a system load of the previous RVU and how, as needed, to revert the CLIM software and/or firmware to the previous versions. NOTE: If your NonStop system does not have CLIMs installed, disregard the sections in this chapter that describe CLIM fallback procedures. Alerts Before performing a system load: • Before halting the processors, stop running applications, including TMF.
software adds approximately one hour for each CLIM to the process of loading the system on the previous RVU. NOTE: When you fall back, you must restore CLIM configuration files saved from the same RVU as the NonStop system RVU to which you are falling back. The procedure for falling back on the CLIM and loading the NonStop system on the previous RVU is: 1. Before halting the processors: a. Prepare to fall back to the previous CLIM firmware. b.
Following are preparatory steps for downgrading to a previous version of the CLIM software. 1. Obtain the password for the root user ID on the CLIM. 2. Obtain a password for the super.super TACL user ID. 3. Obtain the DNS name of each CLIM iLO. The default name is system-climname-ILO, for example, mysys-n100251–ILO. 4.
b. To launch the CLIM Boot Service Configuration Wizard from a NonStop system console, go to the Windows Start menu and select All Programs > HP OSM > CLIM Boot Service Configuration Wizard and launch the wizard. The initial dialog box asks whether you want to "Configure Boot Service on CLIM(s)" or "Disable existing Boot Service on CLIM(s)" and whether or not there is a "peer NSC installed".
c. Select Configure Boot Service on CLIM(s) and the appropriate option for whether or not there is a peer NonStop console installed. (If there is a peer, you are then prompted for the credentials of that peer console.) The next dialog box shows the IP addresses for the one or two CLIMs configured as BOOTP/DHCP servers. d. Check the listed IP addresses to see if they correspond to the CLIMs you are downgrading. If the Hostname fields are empty, no CLIM is configured as a BOOTP server.
6. 7. Obtain the system name, netmask, gateway, and IP address for the CLIMs. If this information is unavailable from your environmental documentation, continue with the next step to obtain it directly from your system. Otherwise, skip the next step. Obtain and record the current CLIM configuration information: a. Using the SCF INFO CLIM, DETAIL command, obtain the maintenance interface IP address and NonStop host system name of the CLIM(s) to be downgraded. For example: ->INFO CLIM $zzcip.
with OSS installed. If you commented out this entry when installing this RVU, use TEDIT to modify the entry as follows: TEDIT $SYSTEM.ZOSSINS.OSSINFIL Then change * SERVER #ZPLS to SERVER #ZPLS This change is required for correct startup of OSS. Migrate CLIM Services and Disconnect CLIMs The H06.15 RVU and earlier H-series RVUs do not support CLIMs. If you are using CLIMs and intend to fall back to H06.15 or an earlier H-series RVU, follow these general guidelines: 1.
In the Halted State, Fall Back to Previous CLIM Firmware (Optional) If you are falling back to previous CLIM firmware using the down system method, use the Down System CLIM Firmware Update Tool. For more information, see the Cluster I/O Protocols (CIP) Configuration and Management Manual and the online help available from within the tool. In the Halted State, Reimage the CLIMs This procedure is necessary only if you are reverting to the previous CLIM software.
3. On the Virtual Media tab, click Virtual Media Applet. 4. Only do this step if you receive the error: With Internet Explorer 7, you must enable the Java applet to use the Virtual Media. a.
Control panel Java 3 Control panel dialog box for Java, Advanced tab Expand
6. This is the default iLO 2 Virtual Media window: a. In the Virtual CD/DVD-ROM area of the dialog box (1 in the following figure), select the image to which you want to reimage or downgrade (2 in the following figure). NOTE: If you do not have the correct image on the console, install the image from a CLIM Software DVD onto the console by following the procedures in the Cluster I/O Protocols (CIP) Configuration and Management Manual.
Use this area (Virtual CD/DVD-ROM) of the applet screen. 2 This is where you specify the local image file. 3 This is where you click Connect. Click Connect beside the Local Media Drive field (3 in the above figure). The DVD image is enclosed with the Green Box, similar to this screen: 1 b. 7. 142 Navigate away from the applet window to the iLO window and select the System Status tab. Then under Last Used Remote Console, click the Launch button for Integrated Remote Console.
8. Select the Power Management Tab and press the Momentary Press button to power up the CLIM. On the pop up, click Yes. 1 2 3 Power management tab. Momentary press tab. Warning pop up.
9. Push Momentary Press again to restart the CLIM. The status now shows that the CLIM is on. 10. Return to the console window. 11. When the Debian splash screen appears, click within its window to activate it, and press Enter.
For G6 CLIMs, only use the Install option: The boot takes a while. 12. When the final screen appears, do not click Continue until you have disconnected the Image File on the Virtual Media.
13. In the iLO browser screen, click on the Virtual Media tab, then press Virtual Media Applet. 14. In the Virtual CD/DVD-ROM area, click Disconnect.
After it is disconnected, it looks like this, and you can continue: 15. Return to the remote console screen and press Enter to cause the program to continue. (Clicking Continue has no effect; you must press Enter.
A status window appears: After a brief pause during which the ProLiant window appears, a screen showing a successful installation like this appears: 148 Falling Back on the CLIMs, Loading the Previous RVU, and Resuming Normal Operations
In the Halted State, Prepare the CLIMs 1. For each CLIM, set the IP address of eth0 via the iLO serial console. a. At the Linux prompt, log onto the CLIM. CLIMs are shipped with two default maintenance interface usernames and passwords: b. • root/hpnonstop • user/clim At the Linux prompt, add the interface by entering this command: climconfig interface –add eth0 c. Add the IP address and bring up the eth0 interface by entering: climconfig ip –add eth0 –ipaddress ip-address -netmask netmask 2.
Be sure to select the CLIM type for the type of CLIM you are configuring from the Mode of operation pull-down menu. After entering the required information in the dialog box, press Configure. Here is an example screen showing the CLIM preparation has successfully completed: 4. 5. Click Yes. The CLIM reboots.
6. For the maintenance provider CLIMs, configure the maintenance provider interface: a. For the two IP CLIMs configured with a Maintenance Provider (usually the first two IP CLIMs, for example, N100251/N100252), configure the eth0:0 interface.
a. b. In the SYSnn field, enter nn, which is the number of the system subvolume that contains the version of the operating system you will load. Under SYSnn and CIIN Option, verify that the CIIN Disabled check box is unchecked. The CIIN file must be enabled because it contains commands needed to start the server. The startup TACL process performs the commands in the CIIN file and then logs off. For a description of the CIIN file, see the appropriate planning guide for your system. 3.
If the reload is initiated successfully, this message appears in a startup TACL window on the system console screen: PROCESSOR RELOAD: nn After Loading the Previous RVU After loading the previous RVU, perform these tasks. If Falling Back to the H06.03 or H06.04 RVU If you are falling back to the H06.03 or H06.04 RVU, then after loading the previous RVU, finish loading the rest of the NonStop Blade Complex firmware, as described in step 6c under “Reverting to H06.03 or H06.04 From This RVU” (page 156).
NOTE: For IP and Telco CLIMs, you must know which CLIMs are configured as failover pairs. For Storage CLIMS, you must know which pair of CLIMs are attached to a particular path or you will lose access to the disk. b. Wait for all the CLIMs to be restored and wait for disk paths or IP addresses to return before rebooting the next CLIM. For Storage CLIMs, use SCF status disk $*. For IP and Telco CLIMs, use CLIMCMD psclim.
c. Selecting Copy HSS Files brings up the Update HSS dialog box. It displays the current HSS version for each processor on the system d. e. Select the desired HSS version from the Available HSS versions drop-down menu. Enter the user name and password for every CLIM and the peer NSC to which the selected HSS file needs to be copied and click Copy.
NOTE: See Support Note SN 12023 (OSM application issues with Administrator user on NSC) for instructions on preventing authentication failures from occurring on NonStop System Consoles when using these OSM tools: Down System CLIM Firmware Update, Update HSS and Copy HSS file actions in OSM low-level link applications, and connecting to a peer NSC from the NonStop Maintenance LAN DHCP DNS Configuration Wizard or the CLIM Boot Service Configuration Wizard.
d) e) f) g) h) i) Right-click the GRP-400 button. Select the Actions option. From the GRP-400 actions list, select Power Cycle All Processors. Click Perform Action. Click OK when asked “Are you sure you want to do a Power Cycle All Processors?” When the Action Status box confirms that the power cycle has successfully completed, close the dialog box. NOTE: It should take approximately five minutes for all processors to complete Power On initialization. 3) c.
NOTE: time. b. c. HP recommends that you update all the NonStop Blade Elements at the same Using the Switch Blade Element Firmware Images dialog box, select Yes to switch the NonStop Blade Element image from shadow to running. Reset the NonStop Blade Elements one at a time. Wait for each NonStop Blade Element to be reintegrated before proceeding. Use the OSM Service Connection Blade Element Reset Action to reset the NonStop Blade Element.
A Using DSM/SCM and NonStop Software Essentials to Install SPRs NOTE: Before performing the steps in this appendix install NonStop Software Essentials by using the procedures in the NonStop Software Essentials Installation and Quick Start Guide. SPRs provide new features between RVUs or correct software problems from a previous RVU. This appendix describes tools available for investigating SPRs and instructions on how to install SPRs.
SPRNOTES You can use SPRNOTES to research an SPR before installing it. Read the installation instructions and considerations documented in the SPRNOTE, which includes: • A summary of SPR contents • Lists of SPRs required for this SPR • Installation considerations, including tasks to perform before and after running DSM/SCM • A summary of problems corrected • A summary of known problems remaining Keep a copy of each SPRNOTE and record the status of the related SPR.
System number Software release ID 2. 000000 H06.03.00 Issue a TACL FILEINFO command on $system.*.osimage to list the SYSnn subvolumes on your system and determine which one is open. $SYSTEM.SYS00 OSIMAGE CODE 0 EOF LAST MODIFIED OWNER 57354240 15DEC1999 9:57 255,255 CODE 0 EOF LAST MODIFIED 57393152 05APR2000 8:56 RWEP NUNU PExt 200 SExt 200 $SYSTEM.SYS01 OSIMAGE 3.
1. 2. From the Configuration Revisions page, select the configuration you are updating and click Create in the New Revision group. The new software revision page appears. Select SPRs to be added to the current configuration and click Copy to. Build the New Revision After you have created a new software revision, prepare to install it on your target systems by building it into an executable form: 1. On the New software revision page, click Build/Apply to load the Build/Apply options page. 2.
> RUN ZPHIRNM $vol.SYSnn where: • $vol specifies the default current system load volume, usually $SYSTEM. • SYSnn specifies the current or new (depending on whether SYSGEN was required) SYSnn subvolume. For example: > RUN ZPHIRNM $system.SYS00 2. 3. When asked if you want to use a log file with the session, enter Y and press Enter. When prompted, enter a file name for the log file. ZPHIRNM issues this message and begins processing: Log file is open, Zphirnm will now begin processing. 4. 5.
tacl>volume $system.template 4. Rename any existing templates: tacl> rename newres, oldres tacl> rename newnres, oldnres 5. Run INSTALL^TEMPLATES to create updated template files: tacl>install^templates newres newnres $system.ztempl NOTE: Running this macro permanently changes the location of the EMS template files. DSM/SCM creates new EMS templates when it creates a new SYSnn.
Before Halting the Processors If you are falling back to the H06.03 or H06.04 RVU, then before halting the processors, update the shadow firmware on each NonStop Blade Element, as described under“Reverting to H06.03 or H06.04 From This RVU” (page 156) . Halt the Processors 1. 2. 3. 4. 5. 6. 7. 8. If necessary, log on to the OSM Low-Level Link application. On the toolbar, select Processor Status to open the Processor Status dialog box. Select the processors to be halted.
B Using DSM/SCM and Planner Interface to Install SPRs SPRs provide new features between RVUs or correct software problems from a previous RVU. This appendix describes tools available for investigating SPRs and instructions on how to install SPRs. CAUTION: Do not apply any SPR to an RVU without first verifying (by using Scout for NonStop Servers, for example) that the SPR can be installed on that specific H-series RVU. See the H06.
• A summary of problems corrected • A summary of known problems remaining Keep a copy of each SPRNOTE and record the status of the related SPR. For example, record whether the SPR is not applicable, is already installed, or needs to be installed. Install SPRs With DSM/SCM The steps for using DSM/SCM to install SPRs are basically the same as those for installing a SUT. Save the Current Configuration First, save the current system configuration database CONFIG file. Use the SCF SAVE command: 1.
$SYSTEM.SYS01 CODE 0 OSIMAGE 3. EOF LAST MODIFIED 57393152 05APR2000 8:56 OWNER RWEP 255,255 NUNU PExt SExt 200 200 At a TACL prompt, enter a STATUS 0,0 command to see which SYSnn subvolume is currently being used: 3> status 0,0 System \ELI Process Pri PFR %WT Userid Program file 0,0 201 P R 000 255,255 $SYSTEM.SYS01.NMONTOR Swap File Name: $SYSTEM.#0 Hometerm $YMIOP.
Build the New Revision After you have created a new software revision, prepare to install it on your target systems by building it into an executable form: 1. In the New software revision dialog box, click Build/Apply to list options for your Build/Apply. The Build/Apply Request dialog box appears with all selections dimmed and unavailable. In a few minutes, the dialog box is refreshed with defaults selected. 2. 3. 4.
Run ZPHIRNM During the Build/Apply phase, DSM/SCM places product files in their subvolumes with temporary (fabricated) file names so that the new files do not conflict with the file names of currently running programs. After the Build/Apply finishes, run the ZPHIRNM program on the target system to: • Rename the files that currently have actual file names with fabricated names. These files become obsolete when the new files are renamed. • 1.
NOTE: If you run the INSTALL^TEMPLATES macro with no arguments, you are prompted to provide required information. For information on the INSTALL^TEMPLATES arguments, print the usage notes: -> volume $system.zinsaids -> load /keep 1/ TACLMACS -> install^templates /out outdev/ help where outdev is the name of the desired output device. 3. Choose a location on $SYSTEM to keep updated template files: tacl>volume $system.template 4.
SECURE ($SYSTEM.TEMPLATE.NEWRES,$SYSTEM.TEMPLATE.NEWNRES),"NUNU" *** INSTALL^TEMPLATES: Completed sucessfully *** If a System Load Is Required If OSM is installed and configured, use these instructions to load your RVU. Before Halting the Processors If you are falling back to the H06.03 or H06.04 RVU, then before halting the processors, update the shadow firmware on each NonStop Blade Element, as described under“Reverting to H06.03 or H06.04 From This RVU” (page 156) . Halt the Processors 1. 2. 3. 4. 5.
C Installing the SWID and DSM/SCM SPRs Using NonStop Software Essentials NOTE: • You must install the minimum DSM/SCM SPR of T6031HO2 ACS or later and NonStop Software Essentials versions T0895V02 AAA (client) or later and T0894V02 AAA (server) before you receive the RVU SUT. Download these products from Scout. When you receive the SUT, the DSM/SCM SPR will be overridden with the one that is on the SUT.
Copy (RESTORE) the H02 DSM/SCM Product Version to Disk (If Necessary) To copy the H02 product version of DSM/SCM and the SWID product from this RVU to disk, at a TACL prompt, enter the RESTORE command: >RESTORE/OUT $S.#nnn.DSM/$tape, ($*.E6031H02.*, *.E9298H02.*, E0894H02.*), VOL $DSMSCM, LISTALL where nnn is the RVU number (H06) and where $tape is the name of the tape drive containing this RVU. Receive the H02 SWID and DSM/SCM SPRs 1. 2. 3. 4. 5. 6. 7. 8.
Create a New Software Revision for H02 DSM/SCM and SWID SPRs 1. In the Configuration Revisions page, select the target system being upgraded and the current revision of the system being upgraded. Select New software revision. The New Software Revision page is loaded with the last software revision that was built for the target in the new revision table. 2. Load the set of products you received into the archive and click Copy to.
a. b. c. Under Perform steps, select Build, apply & process snapshot. Enter the current SYSnn in the Activation SYSnn text box (because no SYSGEN is required). Click Submit Build/Apply. NonStop Software Essentials runs the Build/Apply requests and displays a Status page that is automatically updated at regular intervals. 4. 5.
You must be logged on as a super.super (255, 255) user to run the INSTALL^TEMPLATES macro. This macro cannot be run with the NOWAIT option and takes approximately ten minutes to finish. For detailed instructions on running the INSTALL^TEMPLATES macro, including troubleshooting information, see “If Running INSTALL^TEMPLATES Is Required” (page 163). Restart Applications You can now start your application software.
$Z03N: TCP TCP-T, STARTED 2. If necessary, press Enter to have STARTSCM run the IPM6031 TACL macro automatically. This step takes several minutes. STARTSCM: A new version of DSM/SCM has been installed and IPM6031 needs to be run. You can either exit and run IPM6031 manually or continue and IPM6031 will be run for you. Enter to continue or BREAK to exit.
If you have to fall back, you can use the newly installed client software.
D Installing SWID, DSM/SCM PVU, and Planner Interface (PI) Client Software NOTE: • You must have installed both the DSM/SCM SPR and the corresponding client version before you receive an RVU SUT. All newly shipped NonStop systems will have the latest DSM/SCM SPR installed. The latest DSM/SCM client version is available only on the SUT unless you have ordered new system consoles.
You can also bring up this screen with Help/About; this method leaves the window open until you close it. To install the DSM/SCM client, see “Install the DSM/SCM Client From ZDSMSCM ” (page 187). Copy (RESTORE) the H02 DSM/SCM Product Version to Disk (If Necessary) To copy the H02 product version of DSM/SCM and the SWID product from this RVU to disk, at a TACL prompt, enter the RESTORE command: >RESTORE/OUT $S.#nnn.DSM/$tape, ($*.E6031H02.*, *.E9298H02.
9. Click OK. You are returned to the Receive Software Request dialog box. 10. Click OK to run the request immediately. (The request takes less than 5 minutes to finish.) The Status dialog box appears. Wait until the display for the Request activity summary appears as Complete, and then close the Status window.
11. Select Window>Refresh to update the Software in Archive dialog box to include the received software. Create a New Software Revision for H02 DSM/SCM and SWID SPRs 1. In the Configuration Revisions dialog box, select the target system being upgraded and the current revision of the system being upgraded. Select New software revision. DSM/SCM opens the New dialog box listing the products in the last software revision that was built for the target. Allow several minutes for the dialog box to appear. 2.
and Apply requests are finished and the snapshot is returned. When the Build and Apply requests are finished, the new software is placed in the current SYSnn subvolume. 1. In the New software revision dialog box, click Build/Apply to display the options for your Build/Apply. It might take several minutes for DSM/SCM to assemble the build information. During this time, the Build/Apply Request dialog box appears with all selections dimmed and unavailable.
Rename the Applied DSM/SCM H02 Files By Running ZPHIRNM 1. Stop DSM/SCM: > VOLUME $dsmscm_vol.ZDSMSCM > RUN STOPSCM where $dsmscm_vol is the DSM/SCM volume. 2. Run ZPHIRNM: > RUN ZPHIRNM $volume.SYSnn where SYSnn is the current SYSnn (because no SYSGEN or system load is required). 3. 4. When asked if you want to use a log file with the session, enter Y. When prompted, enter a file name for the log file. ZPHIRNM displays this message: Log file, filename, was successfully created.
> RUN STARTSCM These messages appear: 8> startscm DSM/SCM Process Startup Function - STARTSCM - T6031H02 - (31MAR2003) Copyright Hewlett Packard Development Company L.P. 1993-2003 \ NOTICE: * If the hometerm chosen during INITENV, $zhome, * is not currently in a paused state, STARTSCM and DSM/SCM * server processes may hang indefinitely. Be sure this * hometerm has been paused! Because the $ZHOME reliable home-term process is not an interactive process and is always paused, no action is necessary.
Recovery for Problems While Installing the H02 Version of DSM/SCM If you encounter problems while installing the H02 version of DSM/SCM, see the DSM/SCM User’s Guide. If NonStop Errors Are Displayed See the DSM/SCM EMS Messages manual for information regarding the error message and the DSM/SCM User’s Guide for information on deleting a Build/Apply request.
5. In the Contents pane, double-click dsmscm.ini. Notepad opens the DSM/SCM initialization file. For example: 6. 7. Make a note of the IP address and port number. Close the dsmscm.ini file. Copy the ZDSMSCM Client File From the Host 1. From the Windows Start menu, select Run and enter the command CMD . An example response is: Microsoft Windows XP [Version 5.1.2600] (C) copyright 1985–2001 Microsoft Corp. C:\Documents and Settings\Administrator > 2. 3.
250 CWD command successful 10. Enter: get zdsmexe zdsm.exe. An example response is: 200 PORT command successful. 150 Opening data connection for zdsmexe (192.231.36.1,3212d) (2334 bytes). 226 Binary Transfer complete. ftp: 2334123 bytes received in 0.20 seconds 11441.78Kbytes/sec. ftp> 11. Move the zdsm.exe file into the desired folder on the NonStop console, such as c:\DSMSCM or C:\DSMH06nn. 12. Double click on zdsm.exe to expand the files into the desired folder. Install the DSM/SCM Client Software 1.
3. Click Next to accept the default (private) or type in shared and click Next. NOTE: Private software product groups can be used only by the planner who creates the grouping. Shared software product groups can be used by other planners. For more information on these options, see the DSM/SCM User’s Guide. (NonStop Software Essentials only supports shared product groups and HP recommends using shared product groups for PI as well.
5. Check that WINSOCK is selected. Click Next. The Choose Destination Location dialog box appears with the default path displayed, based on your Windows operating system: 6. Click Next to accept the default.
7. Enter the IP address for the host system with which DSM/SCM communicates (see “Determine the Current IP Address and Port Number” (page 187)), and click Next. NOTE: If DSM/SCM is not currently configured to communicate with a host system, accept the default IP address. You can always change this value later by editing the dsmscm.ini file. You are now prompted to enter an IP port number: 8.
9. Enter the host system name (or \noname if DSM/SCM is not currently configured to communicate with a host system), and click Next to continue. You are asked if you would like to run DSM/SCM. 10. Click No. The setup program adds the DSM/SCM client software to the Windows Start>Programs menu. You can start the DSM/SCM Planner Interface or CNFGINFO tool from the Start>Programs>DSM_SCM submenu.
E Updating SWAN Concentrator CLIP Firmware If necessary, you can update the SWAN or SWAN 2 concentrator CLIP firmware after you have completed a system load of the new RVU. See either the SWAN Concentrator Installation and Support Guide or the SWAN 2 Concentrator Installation and Support Guide.
Glossary A7CINFO file A configuration file distributed with OSS products that contains information on the contents of all pax (archive) files of an OSS DSV. ALLPROCESSORS paragraph A required paragraph in the CONFTEXT configuration file that contains attributes defining the HP NonStop™ operating system image for all system processors. The ALLPROCESSORS paragraph follows the optional DEFINES paragraph.
Distributed Systems Management/Software Configuration Manager (DSM/SCM) A graphical user interface (GUI)-based program that installs new software and creates a new HP NonStop™ operating system. DSM/SCM creates a new software revision and activates the new software on the target system. distribution subvolume (DSV) A subvolume containing program files for a particular software product along with the release version update (RVU) document (softdoc) file for that product.
primitives, routines implicitly called from native-compiled code, emulators for TNS floating-point arithmetic, and emulators for privileged-only or long-running TNS machine operations. Open System Services (OSS) An open system environment available for interactive or programmatic use with the HP NonStop operating system. Processes that run in the OSS environment usually use the OSS application program interface.
Index mod-14 extent boundary., 36 partitioned unstructured files, 36 Symbols $SYSTEM.ZTCPIP, 118 $SYSTEM.
NSKCOM, 70 O OSS EasySetup, 37, 121 large files, 43 Root Name Server $ZPNS, 77, 91 Version 1 filesets, 48 P Pcleanup utility, 117 Planner Interface, changing profile information, 92 PORTCONF file, 119 Post-installation configuring OSS, 120 configuring RDF, 121 configuring SMF, 121 updating TCP/IP configuration files, 118 Preemptable object code, 50 PREVIEW mode, 105 Processor type in CONFTEXT file, 22 Profiles, target, changing information, 78, 92 PROTOCOL file configuration file location, 119 PSTATE, 38