H06.17 Software Installation and Upgrade Guide
with OSS installed. If you commented out this entry when installing this RVU, use TEDIT to modify
the entry as follows:
TEDIT $SYSTEM.ZOSSINS.OSSINFIL
Then change
* SERVER #ZPLS
to
SERVER #ZPLS
This change is required for correct startup of OSS.
Migrate CLIM Services and Disconnect CLIMs
The H06.15 RVU and earlier H-series RVUs do not support CLIMs. If you are using CLIMs and
intend to fall back to H06.15 or an earlier H-series RVU, follow these general guidelines:
1. Use the CLIM Boot Service Configuration Wizard or the NonStop Maintenance LAN DHCP
DNS Configuration Wizard to determine if services such as DHCP, DNS, or BOOTP are
configured on the CLIMs or on the NonStop Console.
2. If the services are configured on any of those CLIMs, you will need to migrate those services
to other CLIMs or to system consoles. See Changing the DHCP, DNS, or BOOTP Server from
CLIMs to System Consoles or Changing the DHCP, DNS, or BOOTP Server from System
Consoles to CLIMs, as appropriate.
3. Disconnect the CLIMs that are installed on the affected system.
If Falling Back to the H06.03 or H06.04 RVU
If you are falling back to the H06.03 or H06.04 RVU, before halting the processors, update the
shadow firmware on each NonStop Blade Element, as described under “Reverting to H06.03 or
H06.04 From This RVU” (page 156).
Halt the Processors
To halt the processors:
1. Log on to the OSM Low-Level Link.
2. On the toolbar, click Processor Status to display the Processor Status dialog box.
3. In the Processor Status box, select all processors.
4. From the Processor Actions list, select Halt.
5. Click Perform action.
6. Click OK when asked “Are you sure you want to do Halts?”
7. When the Action Status box confirms that all processors have halted, close the Processor Status
dialog box.
While the Processors are Halted
While the processors are halted, perform these tasks.
In the Halted State, Power Cycle Processors If Falling Back to the H06.03 or H06.04
RVU
If you are falling back to the H06.03 or H06.04 RVU, then while the processors are halted, power
cycle the processors as described in step 6b under “Reverting to H06.03 or H06.04 From This
RVU” (page 156).
Halt the Processors 137