7. Obtain the system name, netmask, gateway, and IP address for the CLIMs. If this information
is unavailable from your environmental documentation, continue with the next step to obtain
it directly from your system. Otherwise, skip the next step.
8. Obtain and record the current CLIM configuration information:
a. Using the SCF INFO CLIM, DETAIL command, obtain the maintenance interface IP address
and NonStop host system name of the CLIM(s) to be downgraded. For example:
->INFO CLIM $zzcip.c100251,detail
CIP Detailed Info CLIM \NSAA11.$ZZCIP.C100251
Mode....................... IP
Configured Location........ Group 100 , Module 2 , Slot 5 , Port 1
ConnPts.................... 2
X1 Location................ Group 100 , Module 2 , Slot 5 , Port 1
Y1 Location................ Group 100 , Module 3 , Slot 5 , Port 1
SvNet ID 1................. 0x000E0DC6
X2 Location................ Group 100 , Module 2 , Slot 5 , Port 2
Y2 Location................ Group 100 , Module 3 , Slot 5 , Port 2
SvNet ID 2................. 0x000E0EC6
Maintenance Interface IP... 16.107.184.198
Network CLIM Information:
Provider................... CSAM2
Index...................... 1
The NonStop host system name in this example is \NSAA11 and the maintenance interface
IP address is 16.107.184.198.
b. Use the climcmd clim-name climconfig interface -info eth0 command
from a TACL prompt for the CLIMs to obtain the netmask and gateway. For example:
20> climcmd c100251 climconfig interface -info eth0
comForte SSH client version T9999H06_17May2009_comForte_SSH_0086
Interface : eth0
Interface Type : Physical Interface
Jumbo Frame : NO
IP Address : 16.107.184.198
Netmask : 255.255.255.0
ROUTE Details :
- Route Type : Default Route
Destination Address : 0.0.0.0
Netmask : 0.0.0.0
Gateway Address : 16.107.184.1
Metric : 0
Minimum RTO : Unspecified
Auto Negotiation Details :
- Status : on
Line Speed : Not Applicable
Duplex : Not Applicable
Software MAC Address : Unspecified
Termination Info: 0
In this example, the netmask is 255.255.255.0 and there is no gateway configured.
c. Use OSM Low-Level Link to connect to the CLIM and obtain PCI Slot configuration
information.
d. Make note of all values.
If Falling Back to the H06.15 or Earlier RVU: Modify OSSINFIL
If you are falling back to an H06.15 or earlier RVU, before halting the processors, you must restore
the SERVER #ZPLS entry in the OSS subsystem maintenance file OSSINFIL on all systems with OSS
installed. If you commented out this entry when installing this RVU, use TEDIT to modify the entry
as follows:
Before Halting the Processors 137